DGT Series





DGTQ: DIGITAL WEIGHT TRANSMITTER/INDICATOR


  DGTQ: DIGITAL WEIGHT TRANSMITTER/INDICATOR
 
MASTER/REPEATER OPTION (MSTSLV code)
  • Specific programme for use of the indicator as a universal weight repeater or as a multi-scale repeater (MASTER) in combination with DFW/DGT/MCW.

    FUNCTIONING MODES:
  • Multi-scale repeater (MASTER)
    function which allows to repeat up to 32 independent scales, with the possibility of managing their functions, or displaying and printing the sum of the weighs of all the scales.
  • UNIVERSAL weight repeater
    function which allows to repeat the weight of any scales, through the configuration of the input string.

  • Click to learn more.
I/O SECTION
  • RS232/C bidirectional port configurable for connection with external units.
  • RS485 or RS232/C bi-directional port configurable for network connection.
  • PROFIBUS serial interface (DGTQPB model).
  • 2 photomosfet outputs: 150 mA 48 Vac / 150 mA 60 Vdc (NO), with configurable functions.
  • 2 optoisolator photocoupler inputs: 12÷24 Vdc, 5 mA min - 20 mA max, with configurable functions.
  • 16-bit analogue output (DGTQAN model) 4-20mA / 0-5Vdc / 0-10Vdc at choice. Maximum load applicable on the output current: 350Ohm. Minimum load applicable on the output voltage: 10kOhm.
Multipurpose weight indicator/transmitter for panel mounting, 4 dependent or independent channels for direct reading and diagnostics of each connected load cell. The wide range of available interfaces, makes it easy to integrate the weighing with any automation system. CE-M approvable (OIML R-76 / EN 45501).

MAIN FEATURES

  • Easy to use 5-key waterproof keyboard.
  • Highly efficient red LED display with 6 13-mm digits and 6 LEDs for showing active functions.
  • Case for panel mounting in Abs according to DIN standard, 96x96x80 mm (lxhxpx). Perforation 90x88 mm (lxh) for panel mounting.
  • Calibration, Set-Up parameters, configurable from keyboard or from PC with DINI TOOLS
  • Up to 10.000e or multirange 2 x 3000e @ 0,3 µV/d in CE-M approved version for legal for trade use.
  • Up to 1.000.000 displayable divisions with internal resolution up to 3.000.000 points.
  • Up to 8 signal linearization points with DINITOOLS (3 from keypad).
  • A/D 24-bit sigma-delta conversion, up to 200 conv./sec. autoselect.
  • Connectable with up to 8 analogue load cells with 350 Ohm input resistance.
  • Management of a digitally equalised 4-cell weighing system or management of 4 independent weighing systems.
  • Master/Slave management (up to 4 Slaves / 1 Master).
  • From 12 Vdc to 24 Vdc power supply.

MAIN CERTIFICATIONS

  • EC Type Approval (EN45501)
  • OIML R76
  • OIML R61 - MID
  • OIML R51

TRANSMITTER / INDICATOR: FUNCTIONS

  • THROUGH KEYBOARD:
    Zeroing; Semi automatic and presettable tare, print and/or data transmission; ON/Stand-by.
  • SELECTABLE:
    High Resolution Weighing x 10; Net/Gross or lb/kg conversion; Weighs totalisation; Formulation; Approved transmission of the weight to PC/PLC (with ALMEM Alibi memory option); Counting; In/Out Truck weighing; Hold e Peak.
  • EXTERNAL INPUT:
    Simulation of key pressure; Keyboard lock.
  • MOSFET OUTPUT:
    Set Point Control on the weight, either positive (in loading) or negative (in unloading), or on the pieces (counting mode), with programmable enabling/disabling thresholds, as direct check or upon weight stability.
  • SERIAL PORTS:
    On all models: Reading of the net, gross, and tare weights; Clearing; Semi automatic and presettable tare; Scale switch; Setting of outputs activation thresholds; Reading/Writing of Alibi Memory.
    DGTQ and DGTQAN models: Reading of microvolts or ADC converter for all the channels; Message display; Printing; Setting of APW in counting mode; Simulation of key pressure; MODBUS serial protocol.
  • THROUGH 16 bit ANALOGUE OUTPUT (DGTQAN):
    Analogue output proportional to the net or gross weight, either positive (in loading) or negative (in unloading).
DOWNLOAD
Available versions
 CodeDescription
DGTQ Transmitter for panel mounting, with 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing programme.
DGTQAN Transmitter for panel mounting, with 2 IN, 2 OUT, analogue output. 5-key keypad, LED display, and standard weighing programme.
DGTQPB-1 Transmitter for panel mounting, with 2 IN, 2 OUT, Profibus. 5-key keypad, LED display, and standard weighing programme.
Legal for trade approval
 CodeDescription
KCEM Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination to a Dini Argeo indicator.
Storing the weighs (only at time of order)
 CodeDescription
SWM WeiMonitor PC program for monitoring and recording weighs in real time, from one or more scales (price of a license for a single scale management).
Printers/Labellers
 CodeDescription
TPRP(S1) Thermal printer for panel mounting. Fitted with connection cable, 5V power supply (power adapter not included).
TPRPCAL 5V power supplier for TPRP printer.
Communication Interfaces
 CodeDescription
ALMEM(S1) Alibi memory (fiscal memory, max 120.000 weighs) for approved transmission of the weight to PC/PLC or data recording on MMC/USB. Real time clock integrated for print of the date/time.
SETHDIN-1(S1) External RS232 / RS485 to Ethernet converter. Connectable to all Dini Argeo weight indicators via the serial port. ABS case for Omega / DIN bar
Date&Time option
 CodeDescription
DFCLK(S1) Real time clock for printing/displaying of the date and time.
Power supply
 CodeDescription
MDR2012 12Vdc power supplier for DIN bar. 110/240Vac input. CE and UL certified. Incompatible with BOX2121S.
Options for ATEX version
 CodeDescription
ZBA1S Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a hazardous-proof case. Marking: ATEX II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC.
KZBA ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in an explosive zone. Dimensions 180x180x150mm.Can connect up to 4 Load Cell of 350 Ohm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C) for dust.
DCATEXMB4 ATEX declaration of the whole for systems with zener barriers. Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option).
KMB4 Kit of 3 ATEX zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in an hazardous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts.
Other options
 CodeDescription
C4OUT(S1) Set of 4 optoisolated output (mounting and cable gland excluded).
TECSUP Technical assistance by telephone. NET Hourly price.
TECMAN Printed technical manual. (Free, if downloaded from the web). € NET.
UMAN Printed user manual. (Free if downloaded from the web). € NET.

All the specifications and images can be subject to variations and upgrades without prior notice.
ASSISTANCE
DOCUMENTS
SALES NETWORK
CATALOGS