DGT Series





"DGTQF": MICROCONTROLLER FOR INDUSTRIAL DOSAGE SYSTEMS


  "DGTQF": MICROCONTROLLER FOR INDUSTRIAL DOSAGE SYSTEMS
 

DGTQF: microcontroller for industrial dosage systems

DOSAGE CONFIGURATION
High performing microcontroller which, through the simple programming of the parameters, offers the possibility to manage single product dosage systems in loading or in unloading, or multiproduct dosages and mixtures.

Approvals:
CE-M EN 45501, OIML R-76, OIML R-61 (MID), OIML R-51 (MID)

MAIN FEATURES

  • Easy to use 5-key waterproof keyboard.
  • Highly efficient red LED display with 6 13-mm digits and 6 LEDs for showing active functions.
  • Case for panel mounting in Abs according to DIN standard, 96x96x80mm (lxhxp). Panel cutout 90x88 mm (lxh) for panel mounting.
  • A/D 24-bit sigma-delta conversion with 4 channels, up to 400 conv./sec. autoselect.
  • Connectable with up to 8 analogue load cells with 350 Ohm input resistance.
  • Up to 800.000 displayable divisions with internal resolution up to 3.000.000 points.
  • Up to 10.000e or multirange 2 x 3000e @ 0,3 µV/e in CE-M approved version for legal for trade use.
  • Calibration, Set-Up parameters, configurable from keyboard or PC with Dinitools.
  • Up to 8 signal linearization points with DINITOOLS (3 from keypad).
  • Time Date.
  • Memory back-up for recording dosage data in case it’s accidentally turned off.
  • Printing the dosage and consumption data.
  • From 12 Vdc to 24 Vdc power supply.

MAIN CERTIFICATIONS

  • CE-M EN 45501
  • OIML R76
  • OIML R61 - MID
  • OIML R51

I/O SECTION

  • RS232/C bidirectional port configurable for connection with external units.
  • RS485 bidirectional port configurable for network connection.
  • Six 150 mA 48 Vac / 150 mA 60 Vdc (NO) photomosfet outputs configurables according to the selected dosage function.
  • 2 configurable optoisolator photocoupler inputs: 12÷24 Vdc, 5 mA min - 20 mA max for START/STOP dosage.
  • Analogue 16 bit output (only for DGTQFAN model), configurable as 4-20mA, 0-5Vdc or 0-10Vdc. Maximum load applicable on the output current: 300Ohm. Minimum load applicable on the output voltage: 1kOhm.
DOWNLOAD
Available versions
 CodeDescription
DGTQF Microcontroller for dosage, with 2 IN and 6 OUT. 5-key keypad and LED display.
DGTQFAN Microcontroller for dosage, with 2 IN, 6 OUT, analogue output. 5-key keypad and LED display.
RS485 lightning and surge protection
 CodeDescription
RS485PDIN Protection circuit for port 485, with enclosure for DIN rail installation. Protection according to IEC 1000-4-5/D (IEC 801-5/D).
Approval for sale to third parties
 CodeDescription
KCEM Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator.
Printers/Labellers
 CodeDescription
TPRP-1(S1) Panel thermal printer. 5Vdc power supply (power adapter not included). Attention: connection cable kit not included, to be ordered separately.
14TPRC Connection cable kit for TPRP-1.
TPRPCAL 5Vdc power supply unit.
Communication Interfaces
 CodeDescription
SETHDIN-1 RS232 / RS485 / Ethernet converter. Modbus RTU / Modbus TCP/IP (if applicable). Connectable to all Dini Argeo weight indicators via the serial port. ABS housing for DIN rail. With PCB, screw terminals, plastic box and UL marked labels (if applicable).
Connection cables
 CodeDescription
ETHCBRJ(S1) Ethernet cable, l=1,5m. Fitted with fairlead, for connection between indicator and PC network.
Power supply
 CodeDescription
MDR2012 12Vdc power unit for DIN bar. 110/240Vac input. CE and UL certified. Not compatible with BOX2121S.
DR1512 12Vdc power unit for DIN bar. 110/240Vac input.
Options for ATEX version
 CodeDescription
ZBA1S Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
KZBA-1 ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135°C Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT).
DCATEXMB4 ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125°C Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT).
KMB4-1 Kit of 3 ATEX Zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in a dangerous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT).
Other options
 CodeDescription
TECSUP Technical assistance by telephone upon request.
TECMAN Printed technical manual (Free download from the website).
UMAN Printed user manual (Free download from the website).
DACM-NAWI-FR Metrological carnet filled with scale identification (NAWI). The carnet can alternatively be downloaded online (free) from the Dini Argeo website, document section, via the instrument SN. NET PRICE.
ECEMDOC Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET €.

Pdf product page All the specifications and images can be subject to variations and upgrades without prior notice.
ASSISTANCE
DOCUMENTS
SALES NETWORK
CATALOGS