IEC/IECEx products
|
3590EGT-IECEX3GD "TOUCH" : TOUCH SCREEN INDICATOR FOR Ex 2 & 22 ZONES
|
3590EGT-IECEX3GD "TOUCH" : TOUCH SCREEN INDICATOR FOR Ex 2 & 22 ZONES
|
|
|
|
|
| | | AVAILABLE LANGUAGES |
| | - Menu selectable languages:
IT, EN, FR, DE, ES, PT, PL*
* Polish available only on EGT-AF01, EGT-AF02, EGT-AF03, EGT-AF04, EGT-AF09, EGT-BATCH, EGT-BATCH1
Code pages available for the translation of messages and screens, using the Custom Language Tool program (downloadable in the Download section): - Windows 1252: EN, GA, IT, NO, PT, ES, SV, DE, FI, IS, FR, NL, SL
- Windows 1250: PL, CS, SK, HU, SL, SH, RO, SQ, EN, DE
- Windows 1251: RU, UK, BE, BG, SR, MK, EN
- Windows 1253: EL, EN
- Windows 1258: VI, EN, FR
AVAILABLE ON ESTIMATE
- Power supply 24 Vdc.
- PG13,5 anti-friction cable glands with adapters for the passage of cables from 5,5 to 8 mm and from 10,5 to 13 mm.
|
|
|
Weight indicator with a big touch screen display, for ATEX 2 & 22 hazardous zones. ATEX/IECEX marking: II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gases II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. ATEX/IECEX marking with intrinsically safe connection for load cells: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gases. II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Suitable for advanced industrial applications, it's fitted with 3 serial ports, Ethernet communication port, configurable printouts and integrated alibi memory. CE-M approvable (OIML R-76 / EN 45501, OIML R-51 - OIML R-61 - MID for dynamic check weigher AWI). | | | TECHNICAL FEATURES |
| | - 5,7' colour touch screen display.
- Multilanguage software.
- 15-key alphanumerical waterproof keyboard.
- 3-way control light.
- Selectable QWERTY, AZERTY or QWERTZ keyboard integrated in the touch screen.
- Stainless steel waterproof enclosure, with new IP68 protection system.
- Dimensions: 280x143x185mm.
- Suitable for use on the table.
- Real time clock and permanent data storage.
- Alibi memory as standard, integrated on the motherboard.
- Slot for built-in micro SD to record the configuration, logos, and customized screens (upon request).
- Functions available with DINITOOLS utility
- Configuration, data entry and print formatting. - Recording and filing of all the information on PC. - Complete retrieval of the configuration. - Instrument calibration with numeric values. - Customization of the screens. - 24-bit A/D converter, 4 channels, up to 3200 conv./sec. with automatic frequency selection and up to 8 signal linearisation points.
- 4 independent analogue channels for weight reading (up to 2 in E-AF03 version).
- Connection with up to 16 analogue load cells of 350 Ohm (45 load cells of 1000 Ohm).
- Up to 10.000e OIML or multi-range 3 x 3000e @ 0,3 µV/d CE-M legal for trade.
- Up to 1.000.000 displayable divisions for internal factory use, with internal resolution up to 3.000.000 points.
- Connectable to printers and labellers with free programming of the printout formats.
- Power supply from 110-240Vac line or 12-24 Vdc Max. 25.2W
|
| | | I/O SECTION |
| | - 2 RS232 serial ports on terminals, for connection to printer, PC, radio module and optional interfaces.
- 1 RS485/RS232 serial port on terminals, for connection to weight repeater,remote scale, badge readers or digital load cells.
- 4 serial optoisolated outputs, up to 16 with optional board.
- 2 serial optoisolated inputs, up to 8 with optional board.
- Profibus or Modbus/TCP interface to install in safety zone.
- External Profinet, Ethernet/IP, EtherCAT, CANopen and DeviceNet interface to install in safety zone. (optional, only with standard AF01 weighing program).
- Modbus RTU Interface.
- Optional Bluetooth connection, for fast wireless programming of archives, via PC, tablet or smartphone.
- Analog output DAC16O requires IOEXPB expansion board.
|
|
|
Available versions
| Code | Description |
| 3590EGT-IECEX3GD | Ex colour Touch Screen indicator for zone 2/22 with AF01 software. IP68 stainless steel enclosure. ATEX/IECEX II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| 3590EGT-IECEX3GDZB | Ex colour Touch Screen indicator for zone 2/22 with AF01 software, connectable directly to load cells installed in zone 1/21 and 0/20. IP68 stainless steel enclosure. ATEX/IECEX marking: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
Available firmwares
| Code | Description |
| AF02 a> | Software for piece/quantity counting. |
| AF03GT a> | Software for weighbridges, vehicle In/Out. For 3590 "TOUCH SCREEN" weight indicators. |
| AF04GT | Software for statistical checking of prepackaged goods. For 3590 "TOUCH SCREEN" weight indicators. |
| AF05 a> | Software for price computing and industrial labelling. |
| AF08 a> | Software for static wheel and axle weighing with 2 or more pads. |
| AF09 a> | Software for dynamic and static axle weighing with 1 or 2 pads. |
| BATCH1 a> | Software for single product dosage systems in loading and unloading. |
| BATCH a> | Software for multicomponent dosage systems in loading and unloading. NOTE: For 3590, IOEXPB expansion board is required. |
| BATCH1-R61 | Software for single product dosage systems in loading and unloading. OIML R61 approved. |
| CHECK a> | Software for packages weighting on a conveyor belt functions. R61 approvable. |
Optional power supply cords
| Code | Description |
| EXACB4 | (S6) 4x0.5 mm² armoured cable (suitable for Ex zones). PVC inner sheath. Armour: galvanised steel wire braid. Outer sheath PVC, diameter 7.3 mm. Temperature range: -30 / +80 °C. Minimum bending radius >/= 10 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
Declaration of ATEX conformity
| Code | Description |
| DCATEX3GD | Declaration of ATEX conformity of whole. Ex II 3G IIC T6 Gc X and Ex II 3D IIIC T115°C Dc X system, with relative label of whole system, for ATEX certified or NOT ATEX certified Dini Argeo indicator (in the latter case to be installed in a safe area) connected to a mechanical structure with ATEX load cells (each load cell must be certified with CCATEX or CCATEX3GD option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN, DE, FR, ES and IT). |
| DCATEXMB4 | ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125°C Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
(*) DCATEXMB4 compatible only with 3590EGT-IECEX3GDZB.
Approval for sale to third parties
| Code | Description |
| KCEM a> | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
| ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET €. |
| ECEM-AU | Single platform/scale legal-for-trade approval for Australia. |
Printers/Labellers for safe zones
| Code | Description |
| OBTPRB a> | (S1) Table thermal printer. For weight indicator, with IP40 ABS case, 1,5 m connection cable and internal power supply. Thermal paper roll included as standard. |
| CODEPG | Service for loading a customised code-page on TPR printer (standard is PC437 - Central Europe, USA) |
| LP542TE a> | (S1) Thermal transfer or direct thermal labelling machine Supplied with standard peel mechanism. Maximum printing size 25400 x 108 mm. Maximum roll Ø 127 mm and width up to 112 mm.
Label roll and ribbon not included. |
| SMTPLUS-1 a> | (S1) Thermal transfer or direct termal labeller. Peel-off kit in option. Maximum print size 25400 x 108 mm. Maximum roll Ø 203 mm and width up to 118 mm.
Label roll and ribbon not included. |
| SMTRPK-1 | (S1) Label peel-off and rewind kit for SMTPLUS-1 labeller. |
| PRNSERV | Custom-made ticket (up to 4 layouts). NET price. |
| APRNSERV | Custom-made label (up to 4 layouts). NET price. |
Connection cables
| Code | Description |
| RSCBTW | 4-core twisted shielded cable (2x2x0.34 mm²), for RS485 communication or analogue output. Polyolefin inner sheath. Tinned copper braid shielding. Outer sheath PVC, diameter 7mm. Temperature range: -30 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| ETHCBEX | (S6) Multi-core cable (4x2xAWG24) suitable for Ethernet connections in Ex-zones (connectors and cable gland only installed with S6 service). First shield: aluminium/polyester tape, second shield: tinned copper braid (coverage ≥ 85% - EMC 89/336). Outer sheath: PVC, diameter 6.3mm. Temperature range: -30 / +80 °C. Minimum bending radius >/= 8 x O.D. Minimum length 10 m. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| ETHCBEX10M | (S3) ETHCBEX cable complete with cable gland and connectors. Length 10 m. |
Support brackets
| Code | Description |
| EXSTFR | AISI 304 stainless steel bracket, adjustable inclination. For mounting IECEX weight indicators on the wall. |
| EXSTFI | AISI 304 stainless steel wall bracket. For mounting IECEX weight indicators. |
| PANEL-ST | Bracket for mounting the indicator on the panel. |
Storing the weighs
| Code | Description |
| SWM a> | "WeiMonitor" PC program to monitor and record in real time weighs performed on the connected scale (the price is intended for the license to manage one scale). |
Software for display customisation
| Code | Description |
| DDT | Software for the quick customisation of the touchscreen display. For 3590ET and 3590EGT series indicators. |
Communication Interfaces
| Code | Description |
| RF2G4 a> | (S1) Built-in 2.4 GHz radiofrequency module. Max. functioning distance in appropriate environmental and installation conditions: 45m indoors, 140m outdoors. Up to 39 configurable channels. (RF2G4 must be combined with another radio module). |
| WIFITD-3 | (S1) Built-in WI-FI interface. For wireless connection (through access point) to the company computer system. |
| PROFI232-1 a> | External RS232/RS485/PROFIBUS interface for DIN bar. Connectable to the indicators with Profibus protocol with PCB, terminal blocks, plastic box and UL-marked labels (if applicable). |
| BLTH-3 a> | (S1) Built-in bluetooth interface. For wireless connection of the scale to tablets, smartphones, laptops or barcode scanners. Attention: this interface is not suitable for Master-Slave systems. |
| ETHD a> | (S1) Built-in Ethernet interface. Speed from 10 to 100 Mbps, TCP, UDP, IP, ARP, ICMP, Ethernet Mac protocols. |
Fieldbus interfaces
| Code | Description |
| PROFINET1S a> | RS485 to ProfiNET interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
| ETHERNETIP1S a> | RS485 to Ethernet IP interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
| ETHERCAT1S a> | RS485 to EtherCAT interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
| DEVICENET1S a> | RS485 to DeviceNET interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
| CANOPEN1S a> | RS485 to CANOPEN interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
| 191750 | RS485 connection cable for Fieldbus versions to CPU series. Length 20cm. |
| FB1SINST | Installation, configuration and testing of Fieldbus Module 1S. NET PRICE. |
NOTE: not compatible with model 3590EGT-IECEX3GDZB / IOEXPB / DIGIKIT and the AF04 and BATCH weighing programmes.
Display customisation
| Code | Description |
| GTMEM | 10 memories set for display customization with logos and images. |
Digital Input / Output
| Code | Description |
| IOEXPB | (S1) Built-in board with 12 OUT and 6 IN (mounting and cable gland excluded). It includes expansion circuit of the power supply range of the indicator (8-40Vdc). NOT COMPATIBLE WITH 3590E4CH AND TPRXT. With UL marked PCB, Terminal block, plastic box and labels (if applicable). Note: Accessory that can only be ordered in combination with a suitable weight indicator. |
Analog Ouput
| Code | Description |
| DAC16OSER | (S1) Built-in RS232 / RS485 optoisolated analog output, 0-4/20 mA, 0-10VDC . For DFW, 3590 Touch Screen. |
| DAC16O-2 a> | (S1) Built-in optoisolated analog output, 0-4/20 mA, 0-10VDC (cable gland excluded). For DFW, 3590 and CPW indicators. Output -10/+10VDC upon request, only at time of order.
NOTE: For 3590, IOEXPB option board is required, available depending on the model. |
PG cable glands
| Code | Description |
| PG7-IECEX | PG7 Cable Gland for DFW and 3590 IECEx Series Cable diameter: 4 to 7 mm. |
| PG9-IECEX | PG9 Cable Gland for DFW and 3590 IECEx Series Complete with ferrules and seals. Cable diameter: 4 to 7 mm or 7 to 10 mm. |
| PG13-IECEX | PG13 Cable Gland for DFW and 3590 IECEx Series Complete with ferrules and seals. Cable diameter: 5,5 to 8 mm, 8 to 10,5 mm or 10,5 to 13 mm. |
Other options
| Code | Description |
| TECSUP | Technical assistance by telephone upon request. |
Pdf product page
All the specifications and images can be subject to variations and upgrades without prior notice.
|
|