Off Center





SPSW SERIES SINGLE POINT STAINLESS STEEL LOAD CELLS


  SPSW SERIES SINGLE POINT STAINLESS STEEL LOAD CELLS
 


Wiring Code
Colour
Function
WHITE
OUTPUT +
GREEN
SENSE +
BLUE
INPUT +
RED
OUTPUT -
BLACK
INPUT -
GREY
SENSE -


Stainless steel load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell with maximum dimensions of 500x400 mm.

CAPACITIES (kg): 7.5, 15, 30, 50, 100, 200.

OIML R60. C3 precision class.

17-4 PH stainless steel. IP67 protection.

MAIN FEATURES

  • C3 PRECISION CLASS
  • OFF CENTER LOAD COMPENSATED
  • MADE IN 17-4 PH STAINLESS STEEL
  • IP67 PROTECTION
  • MAX. CAPACITIES FROM 7.5 TO 200 kg
  • FOR PLATFORMS WITH DIMENSIONS UP TO 500 X 400 mm
  • SHIELDED CONNECTION CABLE
  • TEST CERTIFICATE AVAILABLE UPON REQUEST

TECHNICAL FEATURES

  • Minimum load cell verification interval: Vmin = EMax / 10.000-15.000
  • Maximum number of verification intervals: nLC = 3000
  • Full Scale Output: 2mV/V +/- 10%
  • Temperature effect on zero:
    from ±0,0093% F.S./10K to ±0,0140% F.S./10K
  • Temperature effect on full scale output:
    ±0,0117% F.S./10K (-10°C/+20°C)
    ±0,0175% F.S./10K (+20°C/+40°C)
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -10°C/+50°C
  • Creep at nominal load in 30 minutes: ± 0,01% F.S.
  • Maximum tolerated excitation voltage: 15 VDC
  • Input Resistance: 380 ± 15 Ohm
  • Output Resistance: 359 ± 5 Ohm
  • Insulation Resistance at 100V: >1000 MOhm
  • Safe Overload: 150% F.S.
  • Ultimate Overload: 300% F.S.
  • Nominal displacement: < 0.5 mm
  • 6-wire shielded cable, 3m long, 5mm diameter

ATEX Version

  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
    ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
DOWNLOAD
Available versions
 
Code
Plate
Max (mm)
Max
(kg)
SPSW7.5 500 x 4007,5
SPSW15 500 x 40015
SPSW30 500 x 40030
SPSW50 500 x 40050
SPSW100 500 x 400100
SPSW200 500 x 400200
Options for ATEX version
 CodeDescription
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m
LCCBA Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m
EXCB6(S6) Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m
CCATEX-1 Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
CCATEX3GD ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115°C Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT).

Pdf product page All the specifications and images can be subject to variations and upgrades without prior notice.
ASSISTANCE
DOCUMENTS
SALES NETWORK
CATALOGS