Off Center





SPBC SERIES SINGLE POINT LOAD CELLS


  SPBC SERIES SINGLE POINT LOAD CELLS
 





Dimensions (mm)


SPBC Wiring Code
Colour
Function
  --
SHIELD
YELLOW
OUTPUT +
GREY
SENSE +
BROWN
INPUT +
WHITE
OUTPUT -
GREEN
INPUT -
PINK
SENSE -



Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell with maximum dimensions of 700x700 mm.

CAPACITIES (kg): 100, 200, 300, 500, 630.

OIML R60. C3 precision class.

Aluminium alloy. IP65 protection.

MAIN FEATURES

  • C3 PRECISION CLASS
  • OFF CENTER LOAD COMPENSATED
  • MADE IN ALUMINIUM ALLOY
  • IP65 PROTECTION
  • MAX. CAPACITIES FROM 100 TO 630kg
  • FOR PLATFORMS WITH DIMENSIONS UP TO 700 X 700 mm
  • SHIELDED CONNECTION CABLE
  • OIML CERTIFICATE AVAILABLE UPON REQUEST
  • TEST CERTIFICATE AVAILABLE UPON REQUEST

TECHNICAL FEATURES

  • Minimum load cell verification interval: Vmin = EMax / 10.000
  • Maximum number of verification intervals: nLC = 3000
  • Full Scale Output: 2mV/V +/- 10%
  • Combined error: 0,017% of Full Scale Output (F.S.)
  • Temperature effect on zero: 0,0014% /°C
  • Temperature effect on full scale output: 0,0014% /°C
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -20°C/+60°C
  • Creep error after 30 minutes: 0,025% F.S.
  • Maximum tolerated excitation voltage: 15 VDC
  • Input Resistance: 410 ± 20 Ohm
  • Output Resistance: 350 ± 5 Ohm
  • Zero Balance: +/-10% F.S.
  • Insulation Resistance: >1000 MOhm
  • Safe Overload: 150% F.S.
  • Ultimate Overload: 200% F.S.
  • Nominal displacement: < 1mm
  • SPBC 6-wire shielded cable, 3m long, 5mm diameter

ATEX Version

  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
    ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
DOWNLOAD
Available versions
 
Code
Plate
Max (mm)
Max
(kg)
SPBC100 700x700100
SPBC200 700x700200
SPBC300 700x700300
SPBC500 700x700500
SPBC630 700x700630
Options for ATEX version
 CodeDescription
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
LCCBA Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
EXCB6(S6) Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
CCATEX-1 Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
CCATEX3GD ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115°C Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT).

Pdf product page All the specifications and images can be subject to variations and upgrades without prior notice.
ASSISTANCE
DOCUMENTS
SALES NETWORK
CATALOGS