Column, for Weighbridges





DINI ARGEO ANALOGUE COLUMN LOAD CELL, IN STAINLESS STEEL, “RCA” SERIES


  DINI ARGEO ANALOGUE COLUMN LOAD CELL, IN STAINLESS STEEL, “RCA” SERIES
 
RCA LOAD CELL: CONNECTION CABLE


  • Wiring Code
    Colour
    Function
    WHITE
    OUTPUT +
    RED
    INPUT +
    YELLOW
    OUTPUT -
    BLUE
    INPUT -
RCA LOAD CELL: INSTALLATION KIT
  • The KRCA kit allows a correct installation of the RCA load cells below the weighbridge plate
  • The kit consists of an upper cup with anti-rotation system, a lower cup and a two-hole plate for easier and faster fixing. All components are made from nickel-plated steel.
  • Both cups are designed for optimal operation in conjunction with the cell’s self-centring spherical bases, allowing their proper oscillation and return to position.
  • The cups are also fitted with triple function integrated washers:
    - they keep lubricating grease in its place.
    - they simplify the proper positioning and levelling of the cell and support it during installation/maintenance.
    - they protect the system by preventing dirt and water from accumulating on the bottom of the cup, thus maintaining the correct oscillation and mechanical compensation of the load cells over time.
Analogue version of compression load cells, ideal for CE-M approved weighbridges, tanks, silos, etc. Manufactured in STAINLESS STEEL, IP68 protection, 4000 divisions, fitted with “rodent proof” armoured cable.

CAPACITIES (kg): 30000.

OIML R60. C4 precision class.

Load cells with stainless steel body. Degree of protection IP68.

20m Armoured Rodent Resistant Cable, with standard Stainless Steel Armor.

Integrated Surge Arresters as Standard

Low Profile Height of only 130mm.
Version available for ATEX environments.

TECHNICAL FEATURES

  • METROLOGICAL:
  • Rated capacity (Cn): 30t
  • Combined error: ± 0,013 %Cn
  • Temperature effect on zero: 0,0014 %Cn/°C
  • Temperature effect on sensitivity: 0,0011 %Cn/°C
  • Creep error (30 min.): 0,018 %Cn

    LEGAL METROLOGY OIML R60
  • Accuracy class: C4
  • Max. number of intervals (nmax): 4000e OIML
  • Minimum verification interval (vmin): 10000
  • Z= Emax/(2xDR): 4000

    ELECTRICAL
  • Nominal range of excitation voltage: 1 - 15Vdc
  • Rated output at Cn: 2mV/V
  • Zero balance: < ± 2.50%Cn
  • Input resistance: 815 ± 20Ω
  • Output resistance: 700 ± 0.35Ω
  • Current Adjustment: 0,1 %Cn
  • Over voltage protection: 10kA/20kV (8/20µs) - IEC61000-4/5
  • Insulation resistance: 5000MΩ/50V

    GENERAL
  • Service temperature range: -20 ~ +60 °C
  • Compensated temperature range: -10 ~ +40 °C
  • Safe load limit: 150% Emax
  • Ultimate overload: 300% Emax
  • Protection degree IP68
  • Load cells with stainless steel body
  • 4-core armoured cable, PVC sheath, 20m length.
  • Nickel plated steel cable gland.
  • Armoured Anti Rodent Cable with Stainless Steel Armour.
  • Self-centring spherical bases.
  • Equipped with anti-rotation system, to be combined with KRCA cups for proper operation.

ATEX VERSION RCA LOAD CELL

  • An ATEX version of the RCA load cell is available for explosive atmospheres.
  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
    ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
DOWNLOAD
Available versions
 
Code
Max
(kg)
RCA30C430000
Assembly kits
 CodeDescription
KRCA Kit of 2 jointed cups for selfalignment and fixing plate. In galvanised steel.
Junction Box / Boards - Cell cables
 CodeDescription
JB10Q Equalisation box for connection with up to 10 analogue load cells. Reinforced polyester box, with 10 + 1 fairleads. With UL marked PCB, Terminal block, plastic box and labels (if expected).
Protection for junction box/electronic circuits
 CodeDescription
GELBOX(S1) Anti condensation, insulating, and sealing gel. Useful for the protection of the electronic circuits of the weighing system, even in conditions of prolonged immersions in time. Pack of 300ml.
WARNING:
For JB10Q/JB10QD: 1200ml of gel required
Options for ATEX version
 CodeDescription
ZBA1S Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a hazardous-proof case. Marking: ATEX II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Manual and ATEX UE CONFORMITY DECLARATIONS (available in EN, DE, FR, ES and IT).
KZBA ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in an explosive zone. Dimensions 180x180x150mm.Can connect up to 4 Load Cell of 350 Ohm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C) for dust. Manual and ATEX UE CONFORMITY DECLARATIONS (available in EN, DE, FR, ES and IT).
JB4QAI Stainless steel IP66, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
JB4QA ABS IP67, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
EXCB6(S6) Shielded, blue, 6x0,22mm² cable, for EX i (2GD) applications. €/m
KMB4 Kit of 3 ATEX zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in an hazardous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts.
CCATEX-1 Optional ATEX version for single load cell. Categories: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Complete with manual and ATEX EU CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
DCATEXMECH DCATEXMECH: ATEX declaration for the PLATFORM / LOAD CELL ASSEMBLY KIT (for the load cells ATEX declaration see CCATEX-1 code). Option to be offered only if the platform is ordered without the indicator, if so, refer to the chosen weight indicator available certifications.
DCATEXMB4 ATEX declaration of the whole for systems with zener barriers. Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option).

All the specifications and images can be subject to variations and upgrades without prior notice.
ASSISTANCE