Is the website displaying in the correct language? Please confirm or select a different language.

Your region has been set to Italy. Please confirm or select a different region.

PLT Series 350 Ohm Nikel-Plated Load Cell Kits for Assembling Floor Scales

Ideal for creating platforms with four load cells of various sizes and capacities. The kit is made up of 4 350 Ohm IP67 nickel-plated load cells, OIML and NTEP approved, together with adjustable resting feet and an equalization box.

  • Minimum load cell verification interval Vmin = EMax / 10.000
  • Maximum number of verification intervals nLC = 3000
  • Combined error 0,017% of Full Scale Output (F.S.)
  • Nonlinearity ± 0.02% FS
  • Hysteresis ± 0.02% FS
  • Repeatability ± 0.01% FS
  • Full Scale Output 2mV/V ± 0.5%
  • Zero balance ± 1% FS
  • Compensated Temperature Range -10°C/+50°C.
  • Operating Temperature Range -20°C/+60°C.
  • Creep error after 30 minutes <0,02% F.S.
  • Maximum tolerated excitation voltage 15 Vdc
  • Input Resistance 380 ± 20 Ohm
  • Output Resistance 350 ± 5 Ohm
  • Insulation Resistance >5000 MOhm
  • Safe Overload 150% F.S.
  • Ultimate Overload 300% F.S.
  • 6-wire shielded cable, 3.5m long, 5 mm diameter

WARNING:
For JB4Q, JB4QA, JBxQI and JBxQAI: 300ml of gel required

  • Adjustable in height
  • Nikel-plated steel structure
  • Anti-slip base
  • Ipersanitizable
  • Fitted with locking bush

  • Built-in junction and equalisation board
  • IP67 protection from dust and water
  • 1 PG9 Cable gland and 4 PG7 Cable glands

 

Colour
Function
  --
SHIELD
YELLOW
OUTPUT +
GREY
SENSE +
BROWN
INPUT +
WHITE
OUTPUT -
GREEN
INPUT -
PINK
SENSE -

Resources/Downloads

Title View Email Category Type
All Around Dini Argeo Weighing Solutions for Logistics and Warehouses Email Pallet Truck Scales|Pallet Scales|Pallet Weighers|Electric Pallet Truck Scales|ATEX Pallet Truck Scales|Hygienic Pallet Truck Scales|Pallet Weighing|Weighing Forks|Hydraulic Weighing Kits|Counting Scales|Bench Scales|Axle Weighing Scales|In-Motion Axle Scales|Dynamic Axle Weighing|Platforms, Indicators and Accessories|High Resolution Load Cells|Off Center Load Cells|Bending Beam Load Cells|Shear Beam Load Cells|Double Shear Beam Load Cells|Compression Load Cells|Tension Load Cells|Column Load Cells|Mounting Kits|ATEX Load Cells|Hygienic Load Cells Articles

Parts

Available Versions

Part # Description List Price Cart/Quote
PLT405C3 Kit 4 x SBT500, 4 x SBFA, 4 x BLKM12I, 1 x JB4Q (4 IP67 nikel-plated steel load cells with 500kg capacity, 4 nikel-plated steel adjustable resting feet, 4 bushings and IP67 ABS junction box).

Consult

PLT410C3 Kit 4 x SBT1000, 4 x SBFA, 4 x BLKM12I, 1 x JB4Q (4 IP67 nikel-plated steel load cells with 1000kg capacity, 4 nikel-plated steel adjustable resting feet, 4 bushings and IP67 ABS junction box).

Consult

PLT420C3 Kit 4 x SBT2000, 4 x SBFA, 4 x BLKM12I, 1 x JB4Q (4 IP67 nikel-plated steel load cells with 2000kg capacity, 4 nikel-plated steel adjustable resting feet, 4 bushings and IP67 ABS junction box).

Consult

Options

Junction Box / Boards - Load Cell Cables

Part # Description List Price Cart/Quote
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).

Consult

LCCBA Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).

Consult

LCCB5C LCCBC cable + 5m extension cable.

Consult

LCCB10C LCCBC cable + 10m extension cable.

Consult

Other Options

Related Products

PLX

PLX1K-1 Series 1000 Ohm Load Cell Kits for Assembling Floor Scales

Ideal for creating platforms with four load cells of various sizes and capacities. The kit is made up of 4 1000 Ohm IP68 stainless steel load cells, OIML approved, together with adjustable stainless steel resting feet and an equalization box.