PLT Series 350 Ohm Nikel-Plated Load Cell Kits for Assembling Floor Scales

Standard Features
Ideal for creating platforms with four load cells of various sizes and capacities. The kit is made up of 4 350 Ohm IP67 nickel-plated load cells, OIML and NTEP approved, together with adjustable resting feet and an equalization box.
Specifications
- Minimum load cell verification interval Vmin = EMax / 10.000
- Maximum number of verification intervals nLC = 3000
- Combined error 0,017% of Full Scale Output (F.S.)
- Nonlinearity ± 0.02% FS
- Hysteresis ± 0.02% FS
- Repeatability ± 0.01% FS
- Full Scale Output 2mV/V ± 0.5%
- Zero balance ± 1% FS
- Compensated Temperature Range -10°C/+50°C.
- Operating Temperature Range -20°C/+60°C.
- Creep error after 30 minutes <0,02% F.S.
- Maximum tolerated excitation voltage 15 Vdc
- Input Resistance 380 ± 20 Ohm
- Output Resistance 350 ± 5 Ohm
- Insulation Resistance >5000 MOhm
- Safe Overload 150% F.S.
- Ultimate Overload 300% F.S.
- 6-wire shielded cable, 3.5m long, 5 mm diameter
WARNING:
For JB4Q, JB4QA, JBxQI and JBxQAI: 300ml of gel required
Resting Feet
- Adjustable in height
- Nikel-plated steel structure
- Anti-slip base
- Ipersanitizable
- Fitted with locking bush
Junction Box
- Built-in junction and equalisation board
- IP67 protection from dust and water
- 1 PG9 Cable gland and 4 PG7 Cable glands
Dimensions (mm)
Wiring Code
Colour
|
Function
|
-- |
SHIELD
|
YELLOW |
OUTPUT +
|
GREY |
SENSE +
|
BROWN |
INPUT +
|
WHITE |
OUTPUT -
|
GREEN |
INPUT -
|
PINK |
SENSE -
|
Parts
Part # | Description |
---|---|
{#Available Versions} | |
PLT405C3 | Kit 4 x SBT500, 4 x SBFA, 4 x BLKM12I, 1 x JB4Q (4 IP67 nikel-plated steel load cells with 500kg capacity, 4 nikel-plated steel adjustable resting feet, 4 bushings and IP67 ABS junction box). |
PLT410C3 | Kit 4 x SBT1000, 4 x SBFA, 4 x BLKM12I, 1 x JB4Q (4 IP67 nikel-plated steel load cells with 1000kg capacity, 4 nikel-plated steel adjustable resting feet, 4 bushings and IP67 ABS junction box). |
PLT420C3 | Kit 4 x SBT2000, 4 x SBFA, 4 x BLKM12I, 1 x JB4Q (4 IP67 nikel-plated steel load cells with 2000kg capacity, 4 nikel-plated steel adjustable resting feet, 4 bushings and IP67 ABS junction box). |
Options
Part # | Description |
---|---|
{#Junction Box / Boards - Load Cell cables} | |
LCCB | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
LCCBA | Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
LCCB5C | LCCBC cable + 5m extension cable. |
LCCB10C | LCCBC cable + 10m extension cable. |
{#Other options} | |
GELBOX | Anti condensation, insulating, and sealing gel. Useful to protect the electronic circuits of the weighing system, even under prolonged immersions conditions. Pack of 300ml. |