|
PW200XRD POWER SUPPLIER FOR ATEX 1 AND 21 ZONES
|
|
|
|
Power adapter and input/output interfacing module, for zones classified as hazardous (zones 1 and 21) with these protection modes:
ATEX II 2(2)G Ex d [ib Gb] IIC T4 Gb and
ATEX II 2(2)D Ex tb [ib Db] IIIC T140°C Db.
|
|
ATEX power supply unit: Available versions
| Code | Description |
| PW200XRD230-1 | ATEX power supplier with 230 Vac input. 10,5 Vdc intrinsically safe output, complete of Exd case, with protection modes: ATEX II 2(2)G Ex d [ib Gb] IIC T4 Gb and ATEX II 2(2)D Ex tb [ib Db] IIIC T140°C Db. Equipped with connecting cable between PW200XRDxxx and DFWATEX2GDxxx with a length of 3 m. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| PW200XRD115 | ATEX power supplier with 115 Vac input. 10,5 Vdc intrinsically safe output, complete of Exd case, with protection modes: ATEX II 2(2)G Ex d [ib Gb] IIC T4 Gb and ATEX II 2(2)D Ex tb [ib Db] IIIC T140°C Db. Equipped with connecting cable between PW200XRDxxx and DFWATEX2GDxxx with a length of 3 m. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| PW200XRD24A | ATEX power supplier with 24 Vac input. 10,5 Vdc intrinsically safe output, complete of Exd case, with protection modes: ATEX II 2(2)G Ex d [ib Gb] IIC T4 Gb and ATEX II 2(2)D Ex tb [ib Db] IIIC T140°C Db. Equipped with connecting cable between PW200XRDxxx and DFWATEX2GDxxx with a length of 3 m. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| PW200XRD24D-1 | ATEX power supplier with 24 Vdc input. 10,5 Vdc intrinsically safe output, complete of Exd case, with protection modes: ATEX II 2(2)G Ex d [ib Gb] IIC T4 Gb and ATEX II 2(2)D Ex tb [ib Db] IIIC T140°C Db. Equipped with connecting cable between PW200XRDxxx and DFWATEX2GDxxx with a length of 3 m. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
Accessories
| Code | Description |
| EXACBPW | (S6) 4x1 mm² armored cable (suitable for Ex zones). PVC compound inner sheath. Armor: galvanized steel wire braid. Outer sheath made of PVC compound, diameter 8.8 mm. Operating temperature: -30 / +80 °C. Minimum bending radius >/= 10 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| PW200IO | Set of 2 ATEX cable glands for PW200XRDxxx. For the use of the INPUT/OUTPUT section on DFWATEX2GDIO or DFWATEX2GDF. |
| PW200IO-1 | Set of 2 ATEX cable glands for PW200XRDxxx-1. For the use of the INPUT/OUTPUT section on DFWATEX2GDIO or DFWATEX2GDF. |