Is the website displaying in the correct language? Please confirm or select a different language.

Your region has been set to Italy. Please confirm or select a  different region.

882IS/882IS Plus Intrinsically Safe Digital Weight Indicator

  • LCD display with white LED backlight
  • T4 temperature rating
  • Battery life display icon
  • Numeric keypad (882IS Plus)
  • Duplex fiber-optic interface
  • Power ON/OFF; battery save mode
  • Configurable local/remote mode
  • I/O module option: one serial port, optional analog output, optional fieldbus cards, Ethernet TCP/IP
  • Time & date (requires I/O module)
  • Setpoint functionality using secondary 920i indicator
  • FM Entity Approved for use in hazardous locations per Rice Lake Weighing Systems control drawing file number 180948

Safe, Accurate Weight Readings in Hazardous Locations 

The intrinsically safe, auto-ranging power supply enables wiring to a single AC conduit line and seal from the safe area. An FM approved, rechargeable battery is also available for isolated power or movable applications. The 882IS utilizes a backlit LCD display to maintain brilliant visibility for user-friendly operation, even in dimly lit areas. Its stainless steel enclosure provides superior protection from the elements.

Enhanced Connectivity

Expand flexibility with an optional safe area I/O Module, featuring a serial port, Ethernet TCP/IP and optional analog output or fieldbus cards for communication with printers, computers and other peripherals. A duplex fiber-optic port allows for electrically-isolated communication with the I/O Module. To complete the IS entity approved system, Rice Lake offers FM/ATEX-approved load cells and junction boxes that interface with the 882IS indicator.

Power:
Input: 5.8 to 7.9 VDC, 100 to 175 mA

Power Consumption:
0.25 W

Battery (optional):
60 hours with 4 × 350 ohm load cells
80 to 100 hours with 1 × 350 ohm load cell
8 to 10 hour charging time

Load Cell Excitation:
3.0 VDC at 87.5 ohm, 4.6 VDC at 700 ohm

Load Cell Current:
34 mA 4 × 350 ohm load cells or 8 × 700 ohm load cells

Load Cell Cabling:
Four- and six- wire with remote sensing (recommended)

Analog Signal Input Range:
-0.5mV/V to 4.0mV/V

Analog Signal Sensitivity:
0.2 μV/graduation minimum
1.5 μV/graduation recommended

 

 

 

Resolution:
Internal: 1,000,000 counts
Display: 10,000
The maximum number of allowed graduations will vary by application

Conversion Rate:
60 updates/second

Annunciators:
Center of Zero, Gross, Net, Motion, lb, kg, oz, g

Motion Band:
Configurable to ± 1 or ± 3 graduations, 1 second delay (or Off)

Display Increments:
1, 2, 5

Display:
Seven-digit, seven-segment LCD display 121 × 24 dot
matrix messaging area with white LED backlight

Keys/Buttons:
Flat membrane panel, tactile feel
882IS:
Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, On/Off
882IS Plus: Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, Full numeric keypad, On/Off

 

Temperature:
14 °F to 104 °F (-10 °C to 40 °C)

Rating/Material:
IP66 enclosure
Stainless steel

Weight:
6.1 lb (2.8 kg)

Warranty:
One-year limited

Intrinsic Safety:
FM/cFM
Class I,II,III, Division 1, Groups ABCDEFG T4
Class I, Zone 0 AEx/Ex ia IIC T4 Ga
Zone 21 AEx/Ex ib IIIC T135°C Db
Ta = -10 °C to 40 °C (14 °F to 104 °F)
ATEX/IECEx
II 1 G Ex ia IIC T4 Ga
II 2 D Ex ib IIIC T135°C Db

Approvals:
NTEP CC 19-015
Measurement Canada AM-6124C
OIML R76/2006-A-NL1-21.11
EU Test Certificate T11166
CE Marked
UKCA
cULus Listed*
FM Entity
EX-ATEX
IECEx
*cULus is only applicable to 882IS I/O and battery charger

Dimensions
Without Battery
A 8.94 in (227 mm) E 9.96 in (253 mm)
B 7.66 in (195 mm) F 4.36 in (111 mm)
C 6.50 in (165 mm) G 8.37 in (213 mm)
D 8.10 in (206 mm)    
With Optional Battery and Tilt Stand
H 4.64 in (118 mm) K 10.29 in (261 mm)
I 5.00 in (127 mm) L 13.06 in (332 mm)
J 9.03 in (229 mm)    

 

 

 

 

Dimensions
Optional Power Supply
A 9.25 in (235 mm) C 3.11 in (79 mm)
B 6.20 in (158 mm)    

 

 

 

 

Dimensions
Optional I/O Module
A 10.00 in (254 mm) D 4.00 in (101.6 mm)
B 9.13 in (231.99 mm) E 2.75 in (69.9 mm)
C 6.91 in (175.5 mm) F 1.50 in (38.1 mm)

 

 

 

 

Resources/Downloads

Title View Email Category Type
Explosion-Proof vs. Intrinsically Safe Equipment Email Intrinsically Safe Articles
What Is Intrinsic Safety? Email Intrinsically Safe Articles

Title Download Email
Explosive Environment Equipment Policy Download Email
Explosive Environment Solutions Download Email
Hazardous Atmospheres Download Email

Title Size Download Email Category
882IS DeviceNet Configuration Files 602 B Download Email Indicators / Controllers
882IS EtherNet/IP Configuration Files 1.6 KB Download Email Indicators / Controllers
882IS Profibus Configuration Files 1.2 KB Download Email Indicators / Controllers
882IS Profinet Configuration Files 2.8 KB Download Email Indicators / Controllers
IPConfig-Utility 3.1 MB Download Email Indicators / Controllers

Title Version Revision Download Email Category Archived
882IS/882IS Plus Intrinsically Safe Indicator Technical Manual (Archived) 1.10 L Download Email Indicators / Controllers|Weight Indicators|Intrinsically Safe Yes
Single Analog Output Option Card for 882D and 882IS Addendum B Download Email Indicators / Controllers|Weight Indicators No
Interface Option Cards for 882D and 882IS Installation and Programming Manual E Download Email Indicator Hardware|Indicators / Controllers|Weight Indicators No
882IS IS6V2 Battery Instructions E Download Email Weight Indicators|Indicators / Controllers|Indicator Hardware No
882IS IS6V2 Battery Charger Instructions E Download Email Indicators / Controllers|Weight Indicators|Indicator Hardware No
882IS Fiber Optics to RS-422 Converter (Archived) C Download Email Indicator Hardware|Indicators / Controllers|Weight Indicators Yes
882IS Fiber Optics to RS-232 Converter D Download Email Weight Indicators|Indicators / Controllers|Indicator Hardware No
882IS/882IS Plus Conditions of Use (Archived) C Download Email Intrinsically Safe|Indicators / Controllers|Weight Indicators Yes
882IS mb-EPS-100-240-X2 Power Supply Instructions A Download Email Indicator Hardware|Indicators / Controllers|Weight Indicators No
882IS I/O Module Installation Manual (Archived) B Download Email Indicators / Controllers|Weight Indicators|Indicator Hardware Yes
882IS Intrinsically Safe Indicator Battery Tester Instruction Addendum A Download Email Indicators / Controllers|Indicator Hardware/Options No
882IS IS6V2 Battery and Barrier Connector Assembly Replacement A Download Email Indicator Hardware/Options No
920i Setpoint Configuration with 882IS/882IS Plus B Download Email Indicator Software|Indicators / Controllers|Weight Indicators No
882IS IS6V2 Battery Charger Instructions (Archived) D Download Email Indicators / Controllers|Weight Indicators|Indicator Hardware Yes

Title Download Email
Hazardous Area Classification Questionnaire Download Email

Title Download Email
882IS/882IS Plus Replacement Parts Catalog Page Download Email

Title Collateral Wizard Request Download Email Category
882IS Performance Series Intrinsically Safe Digital Weight Indicator Request Download Email Indicators / Controllers

Title Version Size Release Date Download Email
882IS IO Module Firmware V1.04.00 1.04.00 177.3 KB 09/04/2025 Download Email
920i iRite with 882IS Setpoints Application 1.01 5.4 KB 02/25/2021 Download Email
Smart Card Fieldbus Firmware for 1280, 880, 882, 882D & 820IS 2.04.00 88.4 KB 10/08/2025 Download Email

Title View Download Email Category
ScaleTalk: What are Hazardous Areas? View Download Email
ScaleTalk: Three Types of Protection for Hazardous Locations View Download Email Intrinsically Safe

Title Download Email
882IS Control Drawing (Archived) Download Email
IS6V2 Battery Control Drawing Download Email
mb-EPS-100-240-X2 Power Supply Control Drawing Download Email

Options

Integrated Fieldbus Port

Part # Description List Price Cart/Quote
190530 882D Opt,Ethernet/IP CompactCom Option

Consult

190531 882D Opt,DeviceNet CompactCom Option

Consult

190532 882D Opt,ProfiNet CompactCom Option

Consult

190534 882D Opt,Profibus CompactCom Option

Consult

190533 882D Opt,Modbus TCP CompactCom Option

Consult

190535 882D Opt,EtherCAT CompactCom Option

Consult

Communication Interfaces