WKPTA - C3: Analogue Kit for Weighbridges with Touch-Screen Indicator

Standard Features
- Touchscreen indicator, specific for weighbridges
- Equalization box with removable terminals and integrated surge arresters
- Analogue load cells in stainless/nickel-plated steel
- Total capacity: 240t (8 x 30t cells)
- OIML R60. C3 precision class
- Load cell height 200mm (including cups height)
- Load cells connection cable length: 20m
Analogue weighbridges kit made up of 3590ET touch screen weight indicator with AF03 software for weighbridges, 8 stainless steel IP68 "RCPT" analogue load cells, complete with galvanized steel oscillating resting joints and equalization box with surge arresters.
3590ET Indicator
- Touch screen, graphic, color display
- ABS waterproof IP65 case
- Integrated alibi memory for CE-M approved communication with printer and PC
- 3 serial ports, 2 RS232 and 1 RS485 for connection to printer, repeater and PC
- 2 inputs and 4 outputs
- AF03 application software suitable for vehicles weighing and weighbridge management, with input/output products check
- AF03GT application software for vehicles weighing and weighbridge management, with input/output products check
RCPT Analogue Load Cells
C3 precision class Stainless steel interior with nickel-plated steel body; laser soldering Optimized for parallel connection IP68 protection rating Capacity 30000kg 18 m shielded connection cable Fitted with self-aligned articulated joints, self-centering plates and protection washer Minimum load cell verification interval: Vmin = EMax / 10.000 |
Maximum number of load cell divisions: nLC = 3000 (C3) Sensitivity: 2mV/V +/- 0,1% Temperature effect on full scale: 0,002% /°C Temperature effect on zero: 0,002% /°C Compensated Temperature Range: -10°C/+40°C Operating Temperature Range: -30°C/+70°C Creep error after 30 minutes: 0,02% F.S. |
Excitation voltage from 5 to 15 VDC Input Resistance: 700 ± 20 Ohm Output Resistance: 703 ± 7 Ohm Zero Balance: +/-1% F.S. Insulation Resistance > 5000 MOhm Safe Overload > 150% F.S. Ultimate Overload: 250% F.S. 4-wire shielded cable, 18m long, 5mm diameter |
JB10Q Junction Box
- Junction box with polyester case.
- Removable terminal blocks.
- IP66 protection rating or IP68 with the use of GELBOX anti condensation gel (optional, you need 1200ml of gel).
- Surge Arresters against electric discharges and disturbances.
Parts
Part # | Description |
---|---|
{#Available Versions} | |
WKPT830A-1 | Kit for ANALOGUE weighbridges with 8 load cells. Composed of 3590ET indicator fitted with AF03 software, 2 inputs, 4 outputs and RS485 port, 8 RCPT30C3-1 analogue load cells with mounting kit, and JB10Q equalisation box with 10 inputs. |
Options
Part # | Description |
---|---|
{#Legal for Trade Approval (only at time of order)} | |
KCEM | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET €. |
{#Protection for junction box / electronic circuits} | |
GELBOX | Anti condensation, insulating, and sealing gel. Useful to protect the electronic circuits of the weighing system, even under prolonged immersions conditions. Pack of 300ml. |
{#Connection Cables} | |
LCCB | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
LCCBA | Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
{#Communication Interfaces} | |
OBRF2G4 | External 2.4 GHz radio module, cable l=3m. ABS IP65 protecting box, 3 m cable, power supply from weight indicator. Max. distance, in appropriate environmental and installation conditions: 45 m indoors, 140m outdoors. 39 configurable channels. |
OBRF2G4-USB | External 2.4 GHz radio frequency module, USB cable l=1m. Power supply directly from the USB port. Max. functioning distance, in appropriate environmental and installation conditions: 45 m indoors, 140 outdoors. 39 configurable channels. |
ETHD | Built-in Ethernet interface. Speed from 10 to 100 Mbps, TCP, UDP, IP, ARP, ICMP, Ethernet Mac protocols. |
RS485OPTO | Built-in optoisolated RS485 interface (mounting and cable gland excluded). |
WIFITD-2 | Built-in WI-FI interface. For wireless connection (through access point) to the company computer system. |
{#Weight Repeaters} | |
GLR100 | RS485 alphanumeric repeater with 110 mm multicolour LED display. Complete with 10m RS485 cable with IP67 connector. |
DGT100R-1 | Weight repeater with 100mm LED display. IP68 stainless steel case, 5-key keypad, air valve for regulating the humidity and the pressure. |
{#Printers / Labelers} | |
OBTPRB | Table thermal printer. For weight indicator, with IP40 ABS case, 1,5 m connection cable and internal power supply. Thermal paper roll included as standard. |
PR80-1 | Thermal printer with paper cutter. |
TM295 | DotMatrix impact printer. Paper / Labels / Tags not included. |
LX300PRO | DotMatrix impact printer. Paper not included. |
RSCBLP | RS232 cable l=1,5m for LP542xx, SMTPLUS, PR80 printers. |
RSCBLP10M | RS232 cable l=10m for LP542xx, SMTPLUS, PR80 printers. |
RSCBLX | RS232 cable l=1,5m for LX300, TM295 printers. |
PRNSERV | Custom-made ticket (up to 4 layouts). NET price. |
APRNSERV | Custom-made label (up to 4 layouts). NET price. |