SPSW A

Standard Features

  • C3 precision class
  • Off center load compensated
  • Made in 17-4 ph stainless steel
  • IP67 protection
  • Max. capacities from 7.5 to 200 kg
  • For platforms with dimensions up to 500 x 400 mm
  • Shielded connection cable
  • Test certificate available upon request

CAPACITIES (kg): 7.5, 15, 30, 50, 100, 200.


OIML R60. C3 precision class.


17-4 PH stainless steel. IP67 protection.

Stainless steel load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell with maximum dimensions of 500x400 mm.

Specifications

Minimum load cell verification interval:
Vmin = EMax / 10.000-15.000

Maximum number of verification intervals:
nLC = 3000

Full Scale Output:
2mV/V +/- 10%

Temperature effect on zero:
from ±0,0093% F.S./10K to ±0,0140% F.S./10K

Temperature effect on full scale output:
±0,0117% F.S./10K (-10°C/+20°C)
±0,0175% F.S./10K (+20°C/+40°C)

Compensated Temperature Range:
-10°C/+40°C

Operating Temperature Range:
-10°C/+50°C

Creep at nominal load in 30 minutes:
± 0,01% F.S.

Maximum tolerated excitation voltage:
15 VDC

Input Resistance:
380 ± 15 Ohm

Output Resistance:
359 ± 5 Ohm

 

Insulation Resistance at 100V:
>1000 MOhm

Safe Overload:
150% F.S.

Ultimate Overload:
300% F.S.

Nominal displacement:
< 0.5 mm

Shielded cable:
6-wire shielded cable, 3m long, 5mm diameter

Wiring Code

Wiring Code
Colour
Function
WHITE
OUTPUT +
GREEN
SENSE +
BLUE
INPUT +
RED
OUTPUT -
BLACK
INPUT -
GREY
SENSE -

ATEX Version

The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:

ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.

The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).

IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.

Dimensions

Code Max
(kg)
Plate Max
(mm)
l
(mm)
w
(mm)
h
(mm)
a
(mm)
b
(mm)
c Ø
(mm)
d
(mm)
e
(mm)
f
(mm)
g
(mm)
i
(mm)
m
(mm)
SPSW7.5  7,5 500 x 400 150 25 40 19 100 N°4 x M6 N°2 x M6 M6 M6 35 13 6,2
SPSW15  15 500 x 400 150 25 40 19 100 N°4 x M6 N°2 x M6 M6 M6 35 13 6,2
SPSW30  30 500 x 400 150 25 40 19 100 N°4 x M6 N°2 x M6 M6 M6 35 13 6,2
SPSW50  50 500 x 400 150 25 40 19 100 N°4 x M6 N°2 x M6 M6 M6 35 13 6,2
SPSW100  100 500 x 400 150 25 40 19 100 N°4 x M6 N°2 x M6 M6 M6 35 13 6,2
SPSW200  200 500 x 400 150 25 40 19 100 N°4 x M6 N°2 x M6 M6 M6 35 13 6,2

Parts

Part # Description
{#Available Versions}
SPSW7.5 Single point approved load cell, C3, Max=7,5kg in stainless steel, IP67 protection degree, 359 Ohm output resistance.
SPSW15 Single point approved load cell, C3, Max=15kg in stainless steel, IP67 protection degree, 359 Ohm output resistance.
SPSW30 Single point approved load cell, C3, Max=30kg in stainless steel, IP67 protection degree, 359 Ohm output resistance.
SPSW50 Single point approved load cell, C3, Max=50kg in stainless steel, IP67 protection degree, 359 Ohm output resistance.
SPSW100 Single point approved load cell, C3, Max=100kg in stainless steel, IP67 protection degree, 359 Ohm output resistance.
SPSW200 Single point approved load cell, C3, Max=200kg in stainless steel, IP67 protection degree, 359 Ohm output resistance.

Options

Part # Description
{#Options for ATEX version}
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
LCCBA Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
EXCB6 Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).