SPO Series Single Point Load Cells
Standard Features
- C3 precision class
- Off center load compensated
- Aluminium alloy construction
- IP67 protection
- Max. capacities from 3 to 40 kg
- For platforms with dimensions up to 300 x 300 mm
- Shielded connection cable
- OIML and test certificates available upon request
CAPACITIES (kg): 3, 5, 10, 15, 20, 30, 40.
OIML R60. C3 precision class.
Aluminium alloy. IP67 protection.
Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell with maximum dimensions of 300x300 mm.
Specifications
|
Minimum load cell verification interval: Maximum number of verification intervals: Full Scale Output: Temperature effect on zero: Temperature effect on full scale output: |
Compensated Temperature Range: Operating Temperature Range: Maximum tolerated excitation voltage: Input Resistance: Output Resistance: |
Insulation Resistance: Safe Overload: Ultimate Overload: Shielded cable: |
Wiring Code
|
Wiring Code
|
|
|
Color
|
Function
|
| YELLOW |
SHIELD
|
| WHITE |
OUTPUT +
|
| BLUE |
INPUT +
|
| RED |
OUTPUT -
|
| BLACK |
INPUT -
|
ATEX Version
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Dimensions

| Code | Max (kg) |
Plate Max (mm) |
l (mm) |
w (mm) |
h (mm) |
a (mm) |
b (mm) |
c Ø (mm) |
d (mm) |
e (mm) |
f (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|
SPO3-1 ![]() |
3 | 150 x 150 | 130 | 25,4 | 22 | 106 | 15 | N°4 x M6 | 25 | 12 | 5 |
SPO5-1 ![]() |
5 | 300 x 300 | 130 | 25,4 | 22 | 106 | 15 | N°4 x M6 | 25 | 12 | 5 |
SPO10-1 ![]() |
10 | 300 x 300 | 130 | 25,4 | 22 | 106 | 15 | N°4 x M6 | 25 | 12 | 5 |
SPO15-1 ![]() |
15 | 300 x 300 | 130 | 25,4 | 22 | 106 | 15 | N°4 x M6 | 25 | 12 | 5 |
SPO20-1 ![]() |
20 | 300 x 300 | 130 | 25,4 | 22 | 106 | 15 | N°4 x M6 | 25 | 12 | 5 |
SPO30-1 ![]() |
30 | 300 x 300 | 130 | 25,4 | 22 | 106 | 15 | N°4 x M6 | 25 | 12 | 5 |
SPO40-1 ![]() |
40 |
300 x 300 | 130 | 30 | 22 | 106 | 15 | N°4 x M6 | 25 | 12 | 5 |
Parts
| Part # | Description |
|---|---|
| Available Versions | |
| SPO3-1 | Single point approved load cell, C3, Max=3kg in aluminium alloy, IP67 protection degree, 350 Ohm output resistance. |
| SPO5-1 | Single point approved load cell, C3, Max=5kg in aluminium alloy, IP67 protection degree, 350 Ohm output resistance. |
| SPO10-1 | Single point approved load cell, C3, Max=10kg in aluminium alloy, IP67 protection rating, 350 Ohm output resistance. |
| SPO15-1 | Single point approved load cell, C3, Max=15kg in aluminium alloy, IP67 protection degree, 350 Ohm output resistance. |
| SPO20-1 | Single point approved load cell, C3, Max=20kg in aluminium alloy, IP67 protection degree, 350 Ohm output resistance. |
| SPO30-1 | Single point approved load cell, C3, Max=30kg in aluminium alloy, IP67 protection degree, 350 Ohm output resistance. |
| SPO40-1 | Single point approved load cell, C3, Max=40kg. Aluminium alloy, IP67 protection degree, 350 Ohm output resistance. |
Options
| Part # | Description |
|---|---|
| Options for ATEX Version | |
| LCCB | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| LCCBA | Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| EXCB6 | Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| CCATEX-1 | Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| CCATEX3GD | ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115°C Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT). |