SPN Series Single Point Load Cells
 
        Standard Features
- C3 precision class
- Off center load compensated
- Aluminium alloy construction
- IP67 protection
- Max. capacities from 300 to 750 kg
- For platforms with dimensions up to 800 x 800 mm
- Shielded connection cable
- OIML certificate available upon request
- Test certificate available upon request
CAPACITIES (kg): 300, 500, 750.
OIML R60. C3 precision class.
Aluminum alloy. IP67 protection.
Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell; maximum platform dimensions of 800x800 mm.
Specifications
| Minimum load cell verification interval:  Maximum number of verification intervals:  Sensitivity: Temperature effect on zero: Temperature effect on Full Span: Compensated Temperature Range:  | Operating Temperature Range: Creep at nominal load in 30 minutes:  Maximum excitation voltage without damage:  Input Resistance:  Output Resistance:  | Insulation Resistance: Mechanical limit load in service: Destructive load:  Deflection at nominal load: Shielded cable:  | 
Wiring Code
| Wiring Code | |
| Colour | Function | 
| YELLOW | SHIELD | 
| WHITE | OUTPUT + | 
| GREEN | SENSE + | 
| BLUE | INPUT + | 
| RED | OUTPUT - | 
| GREY | SENSE - | 
| BLACK | INPUT - | 
ATEX Version
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Dimensions

| Code | Max (kg) | Plate Max (mm) | l (mm) | w | h | a (mm) | b (mm) | c Ø (mm) | d (mm) | e (mm) | f (mm) | g (mm) | i (mm) | m (mm) | n Ø (mm) | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SPN300  | 300 | 800 x 800 | 191 | 76 | 75 | 25 | 60 | N°8 x M8 | 40 | 16 | 12 | 8 | 21 | 18 | 5 | 
| SPN500  | 500 | 800 x 800 | 191 | 76 | 75 | 25 | 60 | N°8 x M8 | 40 | 16 | 12 | 8 | 21 | 18 | 5 | 
| SPN750  | 750 | 800 x 800 | 191 | 76 | 75 | 25 | 60 | N°8 x M8 | 40 | 16 | 12 | 8 | 21 | 18 | 5 | 
Parts
| Part # | Description | 
|---|---|
| Available Versions | |
| SPN300 | Single point approved load cell, C3, Max=300kg in aluminium alloy, IP67 protection degree, 300..500 Ohm output resistance. | 
| SPN500 | Single point approved load cell, C3, Max=500kg in aluminium alloy, IP67 protection degree, 300..500 Ohm output resistance. | 
| SPN750 | Single point approved load cell, C3, Max=750kg in aluminium alloy, IP67 protection degree, 300..500 Ohm output resistance. | 
Options
| Part # | Description | 
|---|---|
| Options for ATEX Version | |
| LCCB | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). | 
| LCCBA | Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). | 
| EXCB6 | Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). | 
| CCATEX-1 | Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). | 
| CCATEX3GD | ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115°C Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT). | 