SPG Series Off-Center Load Cells, C3 Class

As of: Friday, May 9, 2025
Save or Print to PDF
SPG20 0017

Standard Features

  • C3 precision class
  • Off center load compensated
  • Aluminium alloy construction
  • IP67 protection
  • Max. capacities from 10 to 200 kg
  • For platforms with dimensions up to 600 x 600 mm
  • Shielded connection cable
  • OIML certificate available upon request
  • Test certificate available upon request

Approvals

OIML
Atex

CAPACITIES (kg): 10, 15, 20, 30, 50, 100, 200.


OIML R60. C3 precision class.


Aluminium alloy. IP67 protection.

Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell; maximum platform dimensions of 600x600 mm.

Specifications

Minimum load cell verification interval:
Vmin = EMax / 10.000-15.000

Maximum number of verification intervals:
nLC = 3000

Sensitivity:
2mV/V ± 10%

Temperature effect on zero:
7kg: ±0,0084% F.S./10K
10kg: ±0,0070% F.S./10K
18kg: ±0,0070% F.S./10K
36kg: ±0,0070% F.S./10K

Temperature effect on Full Span:
range -10°C/+20°C: 0,0058% F.S./10K
range +20°C/+40°C: 0,0087% F.S./10K

Compensated Temperature Range:
-10°C/+40°C

Operating Temperature Range: -10°C/+50°C

Maximum excitation voltage without damage:
15 Vdc

Input Resistance:
300..500 Ohm

Output Resistance:
300..500 Ohm

Zero Balance:
0 ± 0,12 mV/V (at 100 V)

Insulation Resistance:
>2000 MOhm

Mechanical limit load in service:
150% F.S.

Destructive load:
300% F.S.

Deflection at nominal load:
<0,5mm

Shielded cable:
6-wire shielded cable, 3m long, 4,7mm diameter

 

Wiring Code

Wiring Code
Colour
Function
YELLOW
SHIELD
WHITE
OUTPUT +
GREEN
SENSE +
BLUE
INPUT +
RED
OUTPUT -
GREY
SENSE -
BLACK
INPUT -

ATEX Version

The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:

ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.

The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).

IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.

Dimensions

Code Max
(kg)
Plate Max
(mm) 

l
(mm)

w
(mm)
h
(mm)
a
(mm)
b
(mm)
c Ø
(mm)
d
(mm)
e
(mm)
f
(mm)
SPG10-1 10 300 x 300 150 25,4 40 19,1 19,1 N°8 x M6 34 16 6,1
SPG15-1 15 450 x 450 150 25,4 40 19,1 19,1 N°8 x M6  34 16 6,1
SPG20-1 20 450 x 450 150 25,4 40 19,1 19,1 N°8 x M6  34 16 6,1
SPG30-1 30 450 x 450 150 25,4 40 19,1 19,1 N°8 x M6  34 16 6,1
SPG50-1 50 600 x 600 150 25,4 40 19,1 19,1 N°8 x M6  34 16 6,1
SPG100-1 100 600 x 600 150 25,4 40 19,1 19,1 N°8 x M6  34 16 6,1
SPG200-1

200

600 x 600 150 30 40 19,1 19,1 N°8 x M6  34 16 6,1

Parts

Part # Description
{#Available Versions}
SPG10-1 Single point approved load cell, C3, Max=10kg in aluminium alloy, IP67 protection degree, 300..500 Ohm output resistance.
SPG15-1 Single point approved load cell, C3, Max=15kg in aluminium alloy, IP67 protection degree, 300..500 Ohm output resistance.
SPG20-1 Single point approved load cell, C3, Max=20kg in aluminium alloy, IP67 protection degree, 300..500 Ohm output resistance.
SPG30-1 Single point approved load cell, C3, Max=30kg in aluminium alloy, IP67 protection degree, 300..500 Ohm output resistance.
SPG50-1 Single point approved load cell, C3, Max=50kg in aluminium alloy, IP67 protection degree, 300..500 Ohm output resistance.
SPG100-1 Single point approved load cell, C3, Max=100kg in aluminium alloy, IP67 protection degree, 300..500 Ohm output resistance.
SPG200-1 Single point approved load cell, C3, Max=200kg in aluminium alloy, IP67 protection degree, 300..500 Ohm output resistance.

Options

Part # Description
{#Options for ATEX version}
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
LCCBA Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
EXCB6 Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
CCATEX-1 Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
CCATEX3GD ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115°C Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT).

Dini Argeo S.r.l. | Via della Fisica, 20 - 41042, Spezzano di Fiorano, Modena (MO), Italy | Tel.: +39 0536 843418

www.diniargeo.com