SPBC Series Off-Center Load Cells
 
        Standard Features
- C3 precision class
- Off center load compensated
- Made in aluminium alloy
- IP65 protection
- capacities from 100 to 630kg
- For platforms with dimensions up to 700 x 700 mm
- Shielded connection cable
- OIML certificate available upon request
- Test certificate available upon request
CAPACITIES (kg): 100, 200, 300, 500, 630.
OIML R60. C3 precision class.
Aluminium alloy. IP65 protection.
Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell with maximum dimensions of 700x700 mm.
Specifications
| Minimum load cell verification interval: Maximum number of verification intervals:  Full Scale Output:  Combined error: Temperature effect on zero: Temperature effect on full scale output:  | Compensated Temperature Range: Operating Temperature Range: Creep error after 30 minutes:  Maximum tolerated excitation voltage: Input Resistance:  Output Resistance:  | Zero Balance: Insulation Resistance: Safe Overload: Ultimate Overload:  Nominal displacement: Shielded cable:  | 
Wiring Code
| SPBC Wiring Code | |
| Colour | Function | 
| -- | SHIELD | 
| YELLOW | OUTPUT + | 
| GREY | SENSE + | 
| BROWN | INPUT + | 
| WHITE | OUTPUT - | 
| GREEN | INPUT - | 
| PINK | SENSE - | 
ATEX Version
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Dimensions

| Code | Max (kg) | Plate Max (mm) | l (mm) | w (mm) | h (mm) | a | b (mm) | c Ø (mm) | d (mm) | e (mm) | f (mm) | g (mm) | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SPBC100  | 100 | 700 x 700 | 190 | 73 | 47 | 25 | 60 | N°8 x M8 | 40 | 15 | 7,5 | 6,5 | 
| SPBC200  | 200 | 700 x 700 | 190 | 73 | 47 | 25 | 60 | N°8 x M8 | 40 | 15 | 7,5 | 6,5 | 
| SPBC300  | 300 | 700 x 700 | 190 | 73 | 47 | 25 | 60 | N°8 x M8 | 40 | 15 | 7,5 | 6,5 | 
| SPBC500  | 500 | 700 x 700 | 190 | 73 | 47 | 25 | 60 | N°8 x M8 | 40 | 15 | 7,5 | 6,5 | 
| SPBC630  | 630 | 700 x 700 | 190 | 73 | 47 | 25 | 60 | N°8 x M8 | 40 | 15 | 7,5 | 6,5 | 
Parts
| Part # | Description | 
|---|---|
| Available Versions | |
| SPBC100 | Single point approved load cell, C3, Max=100kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance. | 
| SPBC200 | Single point approved load cell, C3, Max=200kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance. | 
| SPBC300 | Single point approved load cell, C3, Max=300kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance. | 
| SPBC500 | Single point approved load cell, C3, Max=500kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance. | 
| SPBC630 | Single point approved load cell, C3, Max=630kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance. | 
Options
| Part # | Description | 
|---|---|
| Options for ATEX Version | |
| LCCB | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). | 
| LCCBA | Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). | 
| EXCB6 | Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). | 
| CCATEX-1 | Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). | 
| CCATEX3GD | ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115°C Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT). | 