SPBC Series Off-Center Load Cells

As of: Friday, May 9, 2025
Save or Print to PDF
SPBC

Standard Features

  • C3 precision class
  • Off center load compensated
  • Made in aluminium alloy
  • IP65 protection
  • capacities from 100 to 630kg
  • For platforms with dimensions up to 700 x 700 mm
  • Shielded connection cable
  • OIML certificate available upon request
  • Test certificate available upon request

CAPACITIES (kg): 100, 200, 300, 500, 630.


OIML R60. C3 precision class.


Aluminium alloy. IP65 protection.

Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell with maximum dimensions of 700x700 mm.

Specifications

Minimum load cell verification interval:
Vmin = EMax / 10.000

Maximum number of verification intervals:
nLC = 3000

Full Scale Output:
2mV/V +/- 10%

Combined error:
0,017% of Full Scale Output (F.S.)

Temperature effect on zero:
0,0014% /°C

Temperature effect on full scale output:
0,0014% /°C

Compensated Temperature Range:
-10°C/+40°C

Operating Temperature Range:
-20°C/+60°C

Creep error after 30 minutes:
0,025% F.S.

Maximum tolerated excitation voltage:
15 VDC

Input Resistance:
410 ± 20 Ohm

Output Resistance:
350 ± 5 Ohm

Zero Balance:
+/-10% F.S.

Insulation Resistance:
>1000 MOhm

Safe Overload:
150% F.S.

Ultimate Overload:
200% F.S.

Nominal displacement:
< 1mm

Shielded cable:
SPBC 6-wire shielded cable, 3m long, 5mm diameter

Wiring Code

SPBC Wiring Code
Colour
Function
  --
SHIELD
YELLOW
OUTPUT +
GREY
SENSE +
BROWN
INPUT +
WHITE
OUTPUT -
GREEN
INPUT -
PINK
SENSE -

ATEX Version

The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:

ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.

The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).

IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.

Dimensions

Code Max
(kg)
Plate
Max 
(mm)
l
(mm)
w
(mm)
h
(mm)

a
(mm)

b
(mm)
c Ø
(mm)
d
(mm)
e
(mm)
f
(mm)
g
(mm)
SPBC100 100 700 x 700 190 73 47 25 60 N°8 x M8 40 15 7,5 6,5
SPBC200 200 700 x 700 190 73 47 25 60 N°8 x M8 40 15 7,5 6,5
SPBC300 300 700 x 700 190 73 47 25 60 N°8 x M8 40 15 7,5 6,5
SPBC500 500 700 x 700 190 73 47 25 60 N°8 x M8 40 15 7,5 6,5
SPBC630 630 700 x 700 190 73 47 25 60 N°8 x M8 40 15 7,5 6,5

Parts

Part # Description
{#Available Versions}
SPBC100 Single point approved load cell, C3, Max=100kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance.
SPBC200 Single point approved load cell, C3, Max=200kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance.
SPBC300 Single point approved load cell, C3, Max=300kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance.
SPBC500 Single point approved load cell, C3, Max=500kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance.
SPBC630 Single point approved load cell, C3, Max=630kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance.

Options

Part # Description
{#Options for ATEX version}
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
LCCBA Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
EXCB6 Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
CCATEX-1 Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
CCATEX3GD ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115°C Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT).

Dini Argeo S.r.l. | Via della Fisica, 20 - 41042, Spezzano di Fiorano, Modena (MO), Italy | Tel.: +39 0536 843418

www.diniargeo.com