SBX-1KL Series Shear Beam IECEx Load Cells, from 500kg to 2500kg
Standard Features
- C3 precision class
- Stainless steel construction with laser welding
- IP68 protection
- Max. capacities from 500 to 2500 kg
- Shielded connection cable with blue sheath
- Test certificate provided as standard
- IECEx junction box available upon request
- Certification in accordance with the IECEx scheme
CAPACITIES (kg): 500, 1000, 2000, 2500.
OIML R60. C3 precision class.
Stainless steel. IP68 protection.
Output Resistance 1000 Ohm.
These shear beam load cells are certified according to the IECEx scheme for use in potentially explosive atmospheres. Ideal for battery-powered mobile applications, they are designed with a 1000-ohm low-power output resistance. Also suitable for CE-M approved 4-cell scales or for weighing tanks and hoppers, with appropriate accessories.
Specifications
|
Minimum load cell verification interval: Maximum number of verification intervals: Combined error: Full Scale Output: Temperature effect on zero: Temperature effect on full scale output: Compensated Temperature Range: Operating Temperature Range: Creep error after 30 minutes: |
Maximum tolerated excitation voltage: Input Resistance: Output Resistance: Insulation Resistance: Safe Overload: Ultimate Overload: Shielded cable: |
Main certifications OIML R60 Australian legal for trade certificate of approval (NMI S841) Certification according to the IECEx scheme, up to group II category 1G/2D according to standards IEC 60079-0, IEC 60079-7, IEC 60079-11, IEC 60079-31. |
IECEx Certification
- The IECEx Certificate makes the load cell suitable for use in potentially explosive atmospheres with categories:
- Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc per Ta: -20°C~+55°C o Ex ia IIC T6 Ga,
- Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc per Ta: -20°C~+40°C.
- IMPORTANT: Supplied with Ex safety instructions (available in EN, DE, FR and IT).
Wiring Code
|
Colour
|
Function
|
| -- |
SHIELD
|
| YELLOW |
SIG +
|
| GREY |
SENSE +
|
| BROWN |
EXC +
|
| WHITE |
SIG -
|
| GREEN |
EXC -
|
| PINK |
SENSE -
|
Dimensions

Available Versions
| Code | Max (kg) |
|---|---|
SBX500-1KL-BE![]() |
500 |
SBX1000-1KL-BE![]() |
1000 |
SBX2000-1KL-BE![]() |
2000 |
SBX2500-1KL-BE![]() |
2500 |
Parts
| Part # | Description |
|---|---|
| Available Versions | |
| SBX500-1KL-BE | Shear beam approved load cell, C3, Max=500kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C. |
| SBX1000-1KL-BE | Shear beam approved load cell, C3, Max=1000kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C. |
| SBX2000-1KL-BE | Shear beam approved load cell, C3, Max=2000kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C. |
| SBX2500-1KL-BE | Shear beam approved load cell, C3, Max=2500kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C. |
Options
| Part # | Description |
|---|---|
| Joints | |
| AVM12 | Stainless steel/rubber M12 elastic joint for SBX/SBK/SBT cells up to 2500kg. |
| SBJ12 | M12 ball joint for load cells |
| Base Plates | |
| BPSB3 | 3 mm base plate for SBT SBX SBK load cells up to 2500 kg. Size: 55 x 30 x 3 mm |
| BPSB5 | 5 mm base plate for SBT SBX SBK load cells up to 2500 kg. Size: 55 x 30 x 5 mm |
| Mounting kits | |
| KSBN2 | Galvanized steel kit for assembling 1 SBT/SBK/SBX cell from 300 to 2500kg. |
| KSBC2 | Alloy steel kit for assembling 1 SBT/SBK/SBX cell from 300 to 2500kg. |
| KSBX2 | Stainless steel kit for assembling 1 SBT/SBK/SBX cell from 300 to 2500kg. |
| KSB2H | Stainless steel articulated plate with M12x50mm threading. Applicable to SB.. load cells with capacity up to 2000 kg. To combine with BLKM12I bush. |
| Support feet for 4-cell platforms | |
| SBFI-1 | Stainless steel articulated foot with 50 mm non-slip rubber support base. Threading M12 x 1.75 x 43. For SBxx cells up to 2500kg . To combine with BLKM12I bush. |
| KSB2FI-1 | Stainless steel articulated foot with 60 mm non-slip rubber support base. Threading M12 x 1.75 x 46. |
| SBFA | Nickel-plated steel articulated foot with 60 mm non-slip rubber support base. Threading M12 x 1.75 x 45. |
| BLKM12I | Stainless steel M12 bush. |
| Connection Cables | |
| LCCB | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| LCCBA | Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| LCCBM6 | Shielded 6x0,34 mm² cable for moving applications. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| PRCB | Protection sheathing for shielded cable. €/meter internal Ø 15mm. Maximum orderable length: 100 m (longer lengths available only upon request). |
| Available Weight Indicator / Transmitter | |
| DGT1 | Weight transmitter for DIN bar. 5-key keypad, LED display, date/time, alibi memory, and multifunction weighing program. |
| DGT1SX | Weight transmitter on DIN rail, with 2 INPUTS and 4 OUTPUTS. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
| DGT1PX | Panel weight transmitter with aluminum case. 2 IN and 2 OUT. 5-key keypad, LED display. |
| DGT4X | High speed weight transmitter for DIN bar with 4 channels, 2 IN and 2 OUT. 5-key keypad, LED display. |
| Available Weight Indicator / Transmitter | |
| DFWIECEX | IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22. Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT). |
| DFWIECEXAN | IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22. With integrated, intrinsically safe analogue output and additional cable gland. Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT). |
| DFWIECEX-BATCH1 | IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22 for mono-component in-load dosage. With integrated, intrinsically safe RS485 serial port and 4 digital inputs and 12 digital outputs. Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT). |
| DFW-IECEX3GD | Ex Indicator for Zone 2/22. Stainless steel enclosure, IP68 protection, 17-key keypad, backlit LCD display and internal power supply. ATEX/IECEX Marking: II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| DFW-IECEX3GDZB | Ex Indicator for zone 2/22 that can be directly connected to load cells installed in zone 1/21 and 0/20. Stainless steel enclosure, IP68 protection, 17-key keypad, backlit LCD display and internal power supply. ATEX/IECEX Marking: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| 3590EGT-IECEX3GD | Ex colour Touch Screen indicator for zone 2/22 with AF01 software. IP68 stainless steel enclosure. ATEX/IECEX II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| 3590EGT-IECEX3GDZB | Ex colour Touch Screen indicator for zone 2/22 with AF01 software, connectable directly to load cells installed in zone 1/21 and 0/20. IP68 stainless steel enclosure. ATEX/IECEX marking: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| Options for ATEX Version | |
| ZBA1S | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| LCCB | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| EXCB6 | Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |