RL5426 Plus Series, Rice Lake Canister Load Cell, in Stainless Steel

As of: Friday, May 9, 2025
Save or Print to PDF
RL5426 Plus

Standard Features

Canister load cells for CE-M approved weighbridges, tanks, silos, etc. Manufactured in STAINLESS STEEL, IP69K protection degree, 6000 divisions.

CAPACITIES: 20 t, 30 t, 40t, 50 t.


OIML R60. C6 precision class.


Stainless steel body. IP69K Protection Degree.


20 m armoured rat-proof cable with stainless steel armouring as standard.


h= 118,5 mm.

RL5426 Series Specifications

Rated capacity (FS):
20t, 30t, 40t, 50t

Combined error:
0,015 %F.S

Creep error (after 30 min.):
0,01 %FS

Temperature effect on zero:
0,02 %F.S./10°C

Temperature effect on sensitivity:
0,008 %F.S./10°C

Non-linearity error:
0,01%F.S.

Non-repeatability error: 0,006%F.S.


OIML R60:
Vmin= Emax/18000
Accuracy class: C6
Max. number of intervals: 6000e OIML

Gas dischargers to protect against atmospheric discharges

Power Supply:
5÷15 V (AC or DC)

Rated output at F.S.:
2 ± 0.1% mV/V

Input resistance:
800 ± 3Ω

Output resistance:
700 ± 3Ω

Insulation resistance:
5000MΩ

Operating temperature:
-35 ~ +70 °C

Compensated temperature for homologation:
-10 ~ +40 °C

Storage temperature limits:
-40° ~ +80°

Normal service:
120% F.S.

Maximum load / Safe load:
150% F.S.

Ultimate overload:
300% F.S.

IP69K protection degree

Stainless steel body

6-core cable with stainless steel shield, length 20 m, diameter 6mm

Nickel plated steel cable gland with protective spring

Self-centring spherical bases

Equipped with anti-rotation system, to be combined with 173798 cups for proper operation

WARNING:
For JB10Q/JB10QD: 1200ml of gel required

Connection

 

Cable Color Code  
RED
INPUT +
BLACK
INPUT -
GREEN
OUTPUT +
WHITE
OUTPUT -
YELLOW
SENSE +
BLUE
SENSE -
METAL
Shield

Installation Kit

  • The 173798 kit allows a correct installation of the RL5426 load cells below the weighbridge plate.
  • The kit consists of an upper cup and a lower cup with anti-rotation system. All components are made from stainless steel. Both cups are designed for optimal operation in conjunction with the cell’s self-centring spherical bases, allowing their proper oscillation and return to position.

Parts

Part # Description
{#Available versions}
RL5426-20T RL5426 Canister load cell, C6 approved, Max=20t.
RL5426-30T RL5426 Canister load cell, C6 approved, Max=30t.
RL5426-40T RL5426 Canister load cell, C6 approved, Max= 40t.
RL5426-50t RL5426 Canister load cell, C6 approved, Max=50t.
{#Mounting kits}
173798 Cup Set RL5426-01 Stainless Steel Cup Set for RL5426 Load Cells
173801 Tank Mount,RL5426-04N Nickel Plated Tank Mount for RL5426 Load Cells

Options

Part # Description
{#Junction Box / Boards - Load Cell Cables}
JB10Q Equalisation box for connection with up to 10 analogue load cells. Reinforced polyester box, with 10 + 1 cable glands. With surge arresters, PCB, Terminal block, plastic box and UL marked labels (if applicable).
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
LCCBA Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
{#Protection for junction box / electronic circuits}
GELBOX Anti condensation, insulating, and sealing gel. Useful to protect the electronic circuits of the weighing system, even under prolonged immersions conditions. Pack of 300ml.

Dini Argeo S.r.l. | Via della Fisica, 20 - 41042, Spezzano di Fiorano, Modena (MO), Italy | Tel.: +39 0536 843418

www.diniargeo.com