CPX IECEx Series Low Profile Compression Load Cell
Standard Features
- Capacities from 1000 to 10000 kg
- OIML C3 approved, from 2500 to 10000 kg
- Low profile
- Great resistance to lateral forces
- Stainless steel construction
- IP68 protection
- Shielded connection cable with blue sheath
- IECEx junction box available upon request
- Certification in accordance with the IECEx scheme
CAPACITIES (kg): 1000, 2500, 5000, 7500, 10000.
OIML R60, C3 precision class from 2500 to 10000 kg.
Stainless steel. IP68 protection.
These stainless steel compression load cells are designed for potentially explosive atmospheres in accordance with the IECEx scheme. Suitable for weighing tanks and hoppers with the appropriate accessories.
Specifications
|
Minimum load cell verification interval: Full Scale Output: Non-Repeatability: Combined Error: Temperature effect on zero: Temperature effect on full scale output: Compensated Temperature Range: Operating Temperature Range: |
Maximum tolerated excitation voltage: Input Resistance: Output Resistance: Zero Balance: Insulation Resistance: Safe Overload: Shielded cable 4-wire shielded cable, 5,4 mm diameter and 10 m length. |
Main certifications OIML R60 Australian legal for trade certificate of approval (NMI S843) Certification according to the IECEx scheme, up to group II category 1G/2D according to standards IEC 60079-0, IEC 60079-7, IEC 60079-11, IEC 60079-31. |
IECEx Certification
- The IECEx Certificate makes the load cell suitable for use in potentially explosive atmospheres with categories:
Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc per Ta: -20°C~+55°C o Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc per Ta: -20°C~+40°C. - IMPORTANT: Supplied with Ex safety instructions (available in EN, DE, FR and IT).
Wiring Code
|
Wiring Code
|
|
| Colour |
Function
|
| -- |
SHIELD
|
| GREEN |
SIG +
|
| RED |
EXC +
|
| WHITE |
SIG -
|
| BLACK |
EXC -
|
Available versions
| Code | Max (kg) |
|---|---|
| CPX1000-BE | 1000 |
CPX2500-BE![]() |
2500 |
CPX5000-BE![]() |
5000 |
CPX7500-BE![]() |
7500 |
CPX10000-BE![]() |
10000 |
Parts
| Part # | Description |
|---|---|
| Available Versions | |
| CPX1000-BE | Compression load cell, Max=1000kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C. |
| CPX2500-BE | Compression approved load cell, C3, Max=2500kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C. |
| CPX5000-BE | Compression approved load cell, C3, Max=5000kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C. |
| CPX7500-BE | Compression approved load cell, C3, Max=7500kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C. |
| CPX10000-BE | Compression approved load cell, C3, Max=10000kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C. |
Options
| Part # | Description |
|---|---|
| Mounting kits | |
| KCPN10 | Stainless steel kit for assembling a CPX cell, up to 12,500kg and CPA up to 10,000kg (load cell not included). |
| KCPN10A | Nickel steel kit for assembling a CPX cell, up to 12,500kg and CPA cell up to 10,000kg (Load cell not included). |
| KCPN10PRO | UNI EN 1090 stainless steel mounting kit for CPX load cells up to 12.500kg and CPA up to 10.000kg (Load cell not included). |
| Mounting kits | |
| ELGOC | Multipurpose plate with screws. For CPX load cells up to 12.500kg. |
| ELGOP | Fixing plate with screws. For CPX load cells up to 12.500kg. |
| ELGON | Load button to be combined with ELGOC for applications including dummy load cells. |
| Connection Cables | |
| LCCB | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| LCCBA | Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| LCCBM6 | Shielded 6x0,34 mm² cable for moving applications. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| PRCB | Protection sheathing for shielded cable. €/meter internal Ø 15mm. Maximum orderable length: 100 m (longer lengths available only upon request). |
| {#Available Weight Transmitters} | |
| DGT1 | Weight transmitter for DIN bar. 5-key keypad, LED display, date/time, alibi memory, and multifunction weighing program. |
| DGT1SX | Weight transmitter on DIN rail, with 2 INPUTS and 4 OUTPUTS. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
| DGT1PX | Panel weight transmitter with aluminum case. 2 IN and 2 OUT. 5-key keypad, LED display. |
| DGTQ | Transmitter for panel mounting, with 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing program. |
| DGT4X | High speed weight transmitter for DIN bar with 4 channels, 2 IN and 2 OUT. 5-key keypad, LED display. |
| {#Available Weight Indicators} | |
| DFWIECEX | IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22. Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT). |
| DFWIECEXAN | IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22. With integrated, intrinsically safe analogue output and additional cable gland. Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT). |
| DFWIECEX-BATCH1 | IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22 for mono-component in-load dosage. With integrated, intrinsically safe RS485 serial port and 4 digital inputs and 12 digital outputs. Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT). |
| DFW-IECEX3GD | Ex Indicator for Zone 2/22. Stainless steel enclosure, IP68 protection, 17-key keypad, backlit LCD display and internal power supply. ATEX/IECEX Marking: II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| DFW-IECEX3GDZB | Ex Indicator for zone 2/22 that can be directly connected to load cells installed in zone 1/21 and 0/20. Stainless steel enclosure, IP68 protection, 17-key keypad, backlit LCD display and internal power supply. ATEX/IECEX Marking: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| 3590EGT-IECEX3GDZB | Ex colour Touch Screen indicator for zone 2/22 with AF01 software, connectable directly to load cells installed in zone 1/21 and 0/20. IP68 stainless steel enclosure. ATEX/IECEX marking: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| Options for ATEX Version | |
| ZBA1S | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| LCCB | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| EXCB6 | Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |