Standard Features

  • Capacities from 1000 to 10000 kg
  • OIML C3 approved, from 2500 to 10000 kg
  • Low profile
  • Great resistance to lateral forces
  • Stainless steel construction
  • IP68 protection
  • Shielded connection cable with blue sheath
  • IECEx junction box available upon request
  • Certification in accordance with the IECEx scheme

CAPACITIES (kg): 1000, 2500, 5000, 7500, 10000.


OIML R60, C3 precision class from 2500 to 10000 kg.


Stainless steel. IP68 protection.

These stainless steel compression load cells are designed for potentially explosive atmospheres in accordance with the IECEx scheme. Suitable for weighing tanks and hoppers with the appropriate accessories.

Specifications

Minimum load cell verification interval:
Vmin = EMax / 10000

Full Scale Output:
2mV/V +/- 0,5%

Non-Repeatability:
0,01% F.S.

Combined Error:
0,05%

Temperature effect on zero:
0,02% / 10°C

Temperature effect on full scale output:
0,02% / 10°C

Compensated Temperature Range:
-10°C/+40°C

Operating Temperature Range:
-20°C/+60°C

Creep error after 30 minutes:
0,02% F.S.

Maximum tolerated excitation voltage:
15 Vdc

Input Resistance:
750 ± 10 Ohm

Output Resistance:
700 ± 5 Ohm

Zero Balance:
+/-1% F.S.

Insulation Resistance:
>5000 MOhm

Safe Overload:
120% F.S.

Shielded cable 4-wire shielded cable, 5,4 mm diameter and 10 m length.

Main certifications

OIML R60

Australian legal for trade certificate of approval (NMI S843)

Certification according to the IECEx scheme, up to group II category 1G/2D according to standards IEC 60079-0, IEC 60079-7, IEC 60079-11, IEC 60079-31.

 

IECEx Certification

  • The IECEx Certificate makes the load cell suitable for use in potentially explosive atmospheres with categories:
    Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc per Ta: -20°C~+55°C o Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc per Ta: -20°C~+40°C.
  • IMPORTANT: Supplied with Ex safety instructions (available in EN, DE, FR and IT).

Wiring Code

Wiring Code
Colour
Function
  --
SHIELD
GREEN
SIG +
RED
EXC +
WHITE
SIG -
BLACK
EXC -

Available versions

Code Max
(kg)
CPX1000-BE 1000
CPX2500-BE 2500
CPX5000-BE 5000
CPX7500-BE 7500
CPX10000-BE 10000

 

Parts

Part # Description
Available Versions
CPX1000-BE Compression load cell, Max=1000kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C.
CPX2500-BE Compression approved load cell, C3, Max=2500kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C.
CPX5000-BE Compression approved load cell, C3, Max=5000kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C.
CPX7500-BE Compression approved load cell, C3, Max=7500kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C.
CPX10000-BE Compression approved load cell, C3, Max=10000kg. IECEx protection Ex ia IIC T5 Ga, Ex ib IIIC T130°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T80°C Dc for Ta: -20°C~+55°C or Ex ia IIC T6 Ga, Ex ib IIIC T85°C Db, Ex ec IIC T6 Gc, Ex tc IIIC T60°C Dc for Ta: -20°C~+40°C.

Options

Part # Description
Mounting kits
KCPN10 Stainless steel kit for assembling a CPX cell, up to 12,500kg and CPA up to 10,000kg (load cell not included).
KCPN10A Nickel steel kit for assembling a CPX cell, up to 12,500kg and CPA cell up to 10,000kg (Load cell not included).
KCPN10PRO UNI EN 1090 stainless steel mounting kit for CPX load cells up to 12.500kg and CPA up to 10.000kg (Load cell not included).
Mounting kits
ELGOC Multipurpose plate with screws. For CPX load cells up to 12.500kg.
ELGOP Fixing plate with screws. For CPX load cells up to 12.500kg.
ELGON Load button to be combined with ELGOC for applications including dummy load cells.
Connection Cables
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
LCCBA Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
LCCBM6 Shielded 6x0,34 mm² cable for moving applications. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
PRCB Protection sheathing for shielded cable. €/meter internal Ø 15mm. Maximum orderable length: 100 m (longer lengths available only upon request).
{#Available Weight Transmitters}
DGT1 Weight transmitter for DIN bar. 5-key keypad, LED display, date/time, alibi memory, and multifunction weighing program.
DGT1SX Weight transmitter on DIN rail, with 2 INPUTS and 4 OUTPUTS. Fitted with 5-key keypad and LED display. Multifunction weighing program.
DGT1PX Panel weight transmitter with aluminum case. 2 IN and 2 OUT. 5-key keypad, LED display.
DGTQ Transmitter for panel mounting, with 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing program.
DGT4X High speed weight transmitter for DIN bar with 4 channels, 2 IN and 2 OUT. 5-key keypad, LED display.
{#Available Weight Indicators}
DFWIECEX IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22. Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT).
DFWIECEXAN IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22. With integrated, intrinsically safe analogue output and additional cable gland. Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT).
DFWIECEX-BATCH1 IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22 for mono-component in-load dosage. With integrated, intrinsically safe RS485 serial port and 4 digital inputs and 12 digital outputs. Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT).
DFW-IECEX3GD Ex Indicator for Zone 2/22. Stainless steel enclosure, IP68 protection, 17-key keypad, backlit LCD display and internal power supply. ATEX/IECEX Marking: II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
DFW-IECEX3GDZB Ex Indicator for zone 2/22 that can be directly connected to load cells installed in zone 1/21 and 0/20. Stainless steel enclosure, IP68 protection, 17-key keypad, backlit LCD display and internal power supply. ATEX/IECEX Marking: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
3590EGT-IECEX3GDZB Ex colour Touch Screen indicator for zone 2/22 with AF01 software, connectable directly to load cells installed in zone 1/21 and 0/20. IP68 stainless steel enclosure. ATEX/IECEX marking: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
Options for ATEX Version
ZBA1S Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).
EXCB6 Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request).

Dini Argeo S.r.l. | Via della Fisica, 20 - 41042, Spezzano di Fiorano, Modena (MO), Italy | Tel.: +39 0536 843418