CANOPEN interface for single scale or weighing scales network

As of: Saturday, May 10, 2025
Save or Print to PDF
CANOPEN1S

Standard Features

FUNCTIONS FOR HUB CANOPEN UP TO 16 WEIGHING SCALES:

  • This configuration allows to check, at the same time, all the data of the weighing scales network by CANOPEN protocol.
    In detail:
    - NET weight and GROSS weight of the scales
    - Weight status (for example, positive, negative, stable, unstable)
    - Error condition (es. overload, underload)
    - DIGITAL INPUT status
    - RELAY OUTPUT status

CANOPEN CONVERTER FOR SINGLE WEIGHING SCALE:

  • By connecting the CANOPEN to the weighing scale or by selecting one from the scales network, the CANOPEN protocol transmits specific data and controls:
    - NET weight, GROSS weight and TARE of the weighing scale
    - Weight status (for example; positive, negative, stable, unstable)
    - Error condition (es. overload, underload)
    - DIGITAL INPUT status
    - RELAY OUTPUT status
    - SETPOINT output writings
    - Aliby Memory
    - Calibration
    - Configuration SETUP

This CANOPEN interface allows to read the weight from one weighing scale up to 16 weighing scales together, simplyfying the system.

CANOPEN interface for single scale or weighing scales network

Technical Features:

Hub function for a simultaneous check of up to 16 weighing scales.

CANOPEN slave port.

ABS case for panel mounting on DIN bar.

Indexing from 1 to 127.

Baud Rate from 10KBaud to 1MBaud.

Suitable to function with DGT1S weight transmitter. Quick configuration from the transmitter programming menu.

Serial port RS485 (from 9600 to 115200 baud), with "quick connect" system for a fast connection.

Power source: 12-24Vdc.

Upon Request:

UL certificated version

 

Parts

Part # Description
{#Available Versions}
CANOPEN1S RS485 to CANOPEN interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected).

Options

Part # Description
{#Power Supply}
MDR2012 12Vdc power unit for DIN bar. 110/240Vac input. CE and UL certified. Not compatible with BOX2121S.
DR1512 12Vdc power unit for DIN bar. 110/240Vac input.