880/880 Plus Performance™ Series Programmable Weight Indicator/Controller

Standard Features
- LED display
- USB device port connects directly to a PC
- Ethernet TCP/IP polled or continuous polled or continuous, server/client
- Built-in DIN-rail clips on controller box (panel mount)
- Display and controller can be separated up to 250 ft (panel mount)
- Hardware slot for one option card
- Operator functions through menu key for audit trail, preset tare, accumulator, time & date and setpoints
- Audit trail tracking for configuration and calibration changes. Password protection for user and configuration changes.
- 20 setpoints with latched batch engine or unlatched outputs
- Four onboard digital I/O channels
- Programmable ticket formats up to 1,000 characters for header text, gross, net, accumulator and setpoints
- Five-point linearization calibration
- Local/remote operation
- Multi-range or multi-interval weighing
- Filter settings for light, medium and heavy noise
Options
- Analog output
- Relay board
- Fieldbus connectivity
- Dual serial output (v4.00 and newer)
- 24-channel digital I/O (v4.00 and newer)
- Truck in/out program for 100 vehicle IDs
- Adapter plate for converting 310 and 520 panel mounts
- Panel mount kit for universal enclosure
A Weight Indicator with a Range of Connectivity
Designed with the user process in mind and built for communication, Rice Lake’s Performance™ Series weight indicators/controllers are packed with power, yet simple in design. Intuitive multifunction menu keys allow navigation in any application and the NEMA Type 4X/IP69K-rated gasket effectively keeps internal components out of harm’s way. Twenty time- and weight-based setpoints provide ultra responsiveness to handle any process control requirement. For customized operation, use Rice Lake's intuitive iRite software to program functionality specific to the application. The innovative 880 and 880 Plus also accommodate a wide range of connectivity—from USB and RS-232/ RS-485 to Ethernet TCP/IP.
Install an option card for additional fieldbus compatibility, analog output, relay board, dual serial outputs or 24-channel digital inputs/outputs. With two different enclosure types to choose from, Rice Lake’s 880 Performance Series exceeds your expectations wherever you need it.
880 Panel Mount
The sleek design of the 880 not only looks great, it also fits great into existing and new panels alike. At just under five inches deep, the efficiently designed enclosure fits easily into compact spaces with DIN-rail clips to make mounting quick and effortless. The 880’s modular design enables the display to be remotely mounted, especially useful for instances when it is inconvenient to mount the controller on a conventional panel.
880 Plus Universal Enclosure
Equipped with a universal mount, the 880 Plus delivers all of the powerful features of the 880 when a panel mount isn’t necessary. The numeric keypad simplifies the user experience, making operations more convenient and flexible.
880/880 Plus Specifications
Power: Power consumption: Excitation Voltage: Analog Signal Input Range: Analog Signal Sensitivity: A/D Sample Rate: Resolution: System Linearity: Digital I/O: |
(Optional) Analog Output: (Optional) Relay Board: Communication Ports: Annunciators: Display: Keys/Buttons: Dimensions: |
Temperature Range: Rating/Material: Weight: Warranty: EMC Immunity: Approvals: |
880 Panel Mount Dimensions
A | 6.0 in (152 mm) | C | 4.95 in (126 mm) |
B | 4.0 in (102 mm) | D | 0.58 in (14 mm) BEZEL DEPTH |
880 Universal Dimensions
A | 8.10 in (206 mm) | D | 9.87 in (248 mm) |
B | 9.38 in (235 mm) | E | 4.0 in (102 mm) |
C | 8.37 in (213 mm) | F | 6.5 in (165 mm) |
Parts
Part # | Description |
---|---|
{#880 Panel Mount AC Powered (*Power Cord not Included)} | |
177976 | Indicator,880 Panel Mount 5.5, Wider Boards, LED Display, 115-230VAC Power Supply |
{#880 Plus Universal AC Powered} | |
177990 | Indicator,880 Universal LED Display, 115-230VAC with CEE 7/7 Euro Plug |
Options
Part # | Description |
---|---|
{#Option Cards (5.5 in CPU Only)} | |
179156 | Ind Opt,Analog Output 0-10VDC, 0-20mA, 4-20mA used in 880 Indicator |
179157 | Ind Opt,880 Relay Card Four Channel, Dry Contact, 3A @ 115VAC, 5A @ 30VDC. |
{#Network Cards} | |
179159 | Ind Opt,Ethernet/IP Model 880 Indicator |
179160 | Ind Opt,Profinet Model 880 Indicator |
179162 | Ind Opt,Devicenet Model 880 Indicator |
{#Optional Power Supply Cords} | |
PWCORDUK | Version with BS1363 power cord (UK plug). |
PWCORDCH | Power supply cord with SEV1011 plug (CH plug). |