Touch screen 5,7"





3590EGT-IECEX3GD "TOUCH" : TOUCH SCREEN INDICATOR FOR Ex 2 & 22 ZONES


  3590EGT-IECEX3GD "TOUCH" : TOUCH SCREEN INDICATOR FOR Ex 2 & 22 ZONES
 

CUSTOMIZABLE DISPLAYS
  • Thanks to the programmable Touch Screen display, it is possible to create the interface tailored to each application:




  • The PC software "Dini Display Tool" allows for the quick customisation of the TOUCH display.

MAIN CERTIFICATIONS
  • EU Type Examination Certificate (45501:2015)
  • OIML R76
  • OIML R51 - MID
  • OIML R134 (AF09)
  • EN/IEC 60079-0
  • EN/IEC 60079-11 (ZB version)
  • EN/IEC 60079-15
  • EN/IEC 60079-31
  • Certification according to ATEX directive 2014/34/EU and in compliance with IECEx scheme, group II category 3GD according to EN/IEC 60079-0, EN/IEC 60079-11, EN/IEC 60079-15, EN/IEC 60079-31.


    View the certificate
AVAILABLE ON ESTIMATE
  • Power supply 24 Vdc.
  • PG13,5 anti-friction cable glands with adapters for the passage of cables from 5,5 to 8 mm and from 10,5 to 13 mm.
Weight indicator with a big touch screen display, for ATEX 2 & 22 hazardous zones.
ATEX/IECEX marking:
II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gases
II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust.
ATEX/IECEX marking with intrinsically safe connection for load cells:
II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gases.
II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust.
Suitable for advanced industrial applications, it's fitted with 3 serial ports, Ethernet communication port, configurable printouts and integrated alibi memory.
CE-M approvable (OIML R-76 / EN 45501).

WHAT'S NEW

  • IECEx certification.
  • New enclosure with screwless front closure for easy cleaning of the indicator.
  • PG7 and PG9 cable glands with adapters for 4 to 7 mm and 7 to 10 mm cable routing. Equipped with anti-friction system that does not require additional external cable fixing, as required by the IECEx scheme and ATEX directives.
  • Available in specific version for direct connection to load cells installed in zone 1/21 and 0/20.

TECHNICAL FEATURES

  • 5,7' colour touch screen display.
  • Multilanguage software.
  • 15-key alphanumerical waterproof keyboard.
  • 3-way control light.
  • Selectable QWERTY, AZERTY or QWERTZ keyboard integrated in the touch screen.
  • Stainless steel waterproof enclosure, with new IP68 protection system.
  • Dimensions: 280x143x185mm.
  • Suitable for use on the table, column or wall.
  • Real time clock and permanent data storage.
  • Alibi memory as standard, integrated on the motherboard.
  • Slot for built-in micro SD to record the configuration, logos, and customized screens (upon request).
  • Functions available with DINITOOLS utility
    - Configuration, data entry and print formatting.
    - Recording and filing of all the information on PC.
    - Complete retrieval of the configuration.
    - Instrument calibration with numeric values.
    - Customization of the screens.
  • 24-bit A/D converter, 4 channels, up to 3200 conv./sec. with automatic frequency selection and up to 8 signal linearisation points.
  • 4 independent analogue channels for weight reading (up to 2 in E-AF03 version).
  • Connection with up to 16 analogue load cells of 350 Ohm (45 load cells of 1000 Ohm).
  • Up to 10.000e OIML or multi-range 3 x 3000e @ 0,3 µV/d CE-M legal for trade.
  • Up to 1.000.000 displayable divisions for internal factory use, with internal resolution up to 3.000.000 points.
  • Connectable to printers and labellers with free programming of the printout formats.
  • Power supply from 110-240Vac line or 12-24 Vdc Max. 25.2W

COMPLETE PROGRAMMABLITY FOR CUSTOMISED APPLICATIONS

  • Thanks to the integrated development area, fully customised applications can be created independently:
    - Specific weighing softwares according to customer requirements
    - Tailor-made weighing softwares to replace terminals in existing installations
    - Wizards, messaging for the operator
    - Serial port management, protocol customization
    - Complete digital I/O management
    - Sequential or simultaneous automations
    - Data entry, tailor-made archives

    Dini Argeo also offers the service of software development (to be quoted).
STANDARD APPLICATIONS
  • AF01: Totalization and formula weighing (standard)
  • AF02: Piece/quantity counting (optional)
  • AF03: Weighbridges - Vehicle In/Out (optional)
  • AF04: Statistical check of prepackaged goods (optional)
  • AF05: Price computing and industrial labelling (optional)
  • AF08: Static wheel and axle weighing with 2 or more pads (optional)
  • AF09: Software for dynamic or static axle weighing with 1 or 2 pads (optional)
  • BATCH1: Single product dosage systems in loading and unloading (optional)
  • BATCH: Software for multicomponent dosage systems in loading and unloading (optional, requires IOEXPB expansion board)
I/O SECTION
  • 1 Internal serial ETHERNET port, for connection to the company computer system (excludes a serial port).
  • 2 RS232 serial ports on terminals, for connection to printer, PC, radio module and optional interfaces.
  • 1 RS485/RS232 serial port on terminals, for connection to weight repeater,remote scale, badge readers or digital load cells.
  • 4 serial optoisolated outputs, up to 16 with optional board.
  • 2 serial optoisolated inputs, up to 8 with optional board.
  • External Profibus interface (optional), for automation management.
  • Modbus RTU interface.
  • Optional Bluetooth connection, for fast wireless programming of archives, via PC, tablet or smartphone.
  • Analog output DAC16O requires IOEXPB expansion board.
DOWNLOAD
Available versions
 CodeDescription
3590EGT-IECEX3GD Ex colour Touch Screen indicator for zone 2/22 with AF01 software. IP68 stainless steel enclosure. ATEX/IECEX II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Supplied with manual and declaration of conformity (available in EN, FR, DE, ES and IT).
3590EGT-IECEX3GDZB Ex colour Touch Screen indicator for zone 2/22 with AF01 software, connectable directly to load cells installed in zone 1/21 and 0/20. IP68 stainless steel enclosure. ATEX/IECEX marking: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Supplied with manual and declaration of conformity (available in EN, FR, DE, ES and IT).
Available firmwares
 CodeDescription
AF01 Software for totalization and formula weighing.
AF02 Software for piece/quantity counting.
AF03GT Software for weighbridges, vehicle In/Out. For 3590 "TOUCH SCREEN" weight indicators.
AF04GT Software for statistical checking of prepackaged goods. For 3590 "TOUCH SCREEN" weight indicators.
AF05 Software for price computing and industrial labelling.
AF08 Software for static wheel and axle weighing with 2 or more pads.
AF09 Software for dynamic and static axle weighing with 1 or 2 pads.
BATCH1 Software for single product dosage systems in loading and unloading.
BATCH Software for multicomponent dosage systems in loading and unloading. NOTE: For 3590, IOEXPB expansion board is required.
Optional power supply cords
 CodeDescription
EXACB4(S6) Armoured 4x0,5mm² cable, for Ex systems. €/m
Declaration of ATEX conformity
 CodeDescription
DCATEX3GD Declaration of ATEX conformity of whole. Ex II 3G IIC T6 GcX and Ex II 3D IIIC T115°C Dc X system, with relative label of whole system, for Dini Argeo ATEX weight indicator connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). ATEX CONFORMITY DECLARATIONS will be supplied in English.
Approval for sale to third parties
 CodeDescription
KCEM Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator.
ECEMDOC Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET €.
Printers/Labellers for safe zones
 CodeDescription
OBTPRB(S1) Thermal printer in table version. For weight indicator, with IP40 ABS case, 1,5 m connection cable and internal power supply.
LP542S(S1) Direct thermal labeller.
SMTPLUS-1(S1) Thermal transfer or direct termal labeller. Peel-off kit in option.
SMTRPK-1(S1) Label peel-off and rewind kit for SMTPLUS-1 labeller.
PRNSERV Custom-made ticket (up to 4 layouts). NET price.
APRNSERV Custom-made label (up to 4 layouts). NET price.
Connection cables
 CodeDescription
RSCBTW Cable of 2 twisted pairs (€/metre). Double screening for RS422–RS485 connections. 10m minimum length
Storing the weighs
 CodeDescription
SWM "WeiMonitor" PC program to monitor and record in real time weighs performed on the connected scale (the price is intended for the license to manage one scale).
Software for display customisation
 CodeDescription
DDT Software for the quick customisation of the touchscreen display. For 3590ET and 3590EGT series indicators.
Communication Interfaces
 CodeDescription
RFITR-1(S1) Built-in 868 MHz radiofrequency module. Max. functioning distance in appropriate environmental and installation conditions: 70m indoors, 150m outdoors. Up to 50 configurable channels.(RFITR must be combined with another radio module).
WIFITD-2(S1) Built-in WI-FI interface. For wireless connection (through access point) to the company computer system.
PROFI232-1 External RS232/RS485/PROFIBUS interface for DIN bar. Connectable to the indicators with Profibus protocol with PCB, terminal blocks, plastic box and UL-marked labels (if applicable).
BLTH-2(S1) Built-in bluetooth interface. For wireless connection of the scale to tablets, smartphones or laptops. Weighing apps downloadable from Google Play.
Display customisation
 CodeDescription
GTMEM 10 memories set for display customization with logos and images.
Digital Input / Output
 CodeDescription
IOEXPB(S1) Built-in board with 12 OUT and 6 IN (mounting and cable gland excluded). It includes expansion circuit of the power supply range of the indicator (8-40Vdc). NOT COMPATIBLE WITH 3590E4CH AND TPRXT. With UL marked PCB, Terminal block, plastic box and labels (if applicable).
DAC16O-1 (S1) Built-in analog output, 0-4/20 mA, 0-10VdC (cable gland excluded). For DFW, 3590 and CPW indicators. NOTE: For 3590, only with IOEXPB optional board. This interface is not available on its own, always to be combined with a weight indicator when ordering.
Other options
 CodeDescription
TECSUP Technical assistance by telephone upon request.

All the specifications and images can be subject to variations and upgrades without prior notice.
ASSISTANCE
DOCUMENTS
SALES NETWORK
CATALOGS