Weight indicators
|
DFWIECEX-BATCH1 weight indicator, IECEx and ATEX certified, for Zones 1 and 21, 2 and 22, for dosages in hazardous areas
|
DFWIECEX-BATCH1 weight indicator, IECEx and ATEX certified, for Zones 1 and 21, 2 and 22, for dosages in hazardous areas
|
|
|
|
|
| | | Communication Interfaces |
| | - DIGITAL INPUTS/OUTPUTS:
Intrinsically safe 4-input, 12-output digital card with the following specifications: Inputs - Ui: 18 V - Ri: 214 Ω - R input: 859 Ω
Electronic relay outputs - Ui: 18 V - Pi: 1,75 W - In: 70 mA
- Intrinsically safe power supply terminal, for piloting devices in ATEX zone or push-button panel. Output voltage 6V, max current 300mA.
NOTE: by using the available power supply terminal, it is possible to manage the push button panel code EXPHBN in a direct way, even in a safe area, without protection barriers.
OPTIONAL ANALOG OUTPUT: Intrinsically safe analog output, programmable at 0...10Vdc, 0...20mA or 4...20mA. NOTE: It is possible to transmit the signal directly to the safe area using the intrinsically safe protective barrier, code PFANOUTEX for analog output in 0...20mA (or 4...20mA) configuration.
The analogue output of DFWIECEXAN is an active analogue output, which is why it must not be powered. The resistance of analogue input shall be: - If the output signal is in voltage: Rmin=1K - If the output signal is in current: Rmax=300ohm
RS485 SERIAL PORT 2 Optional intrinsically safe RS485 serial ports for communication with repeaters and other devices. - ASCII protocol - Programmable weight string and read command NOTE: it is possible to transmit data directly to the safe area using the protective barrier code PFB485EX
|
|
|
DFWIECEX-BATCH1 weight indicator is the ultimate solution for single product dosages in hazardous areas. Equipped with RGB backlit display to drive the operator during dosage process and new 3 speed management to make a fast, medium and slow speed filling, with fully programmable thresholds. Lance control will handle the lance lifting up.
Up to 50 memories database to store preset dosage targets for a quick recall.
|
|
Available versions
| Code | Description |
| DFWIECEX-BATCH1 | IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22 for mono-component in-load dosage. With integrated, intrinsically safe RS485 serial port and 4 digital inputs and 12 digital outputs. Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT). |
Communication Interfaces
| Code | Description |
| 485IECEX | (S1) Intrinsically safe RS485 serial port , for communication in ATEX zone. Maximum communication distance 200m. (NOTE: for direct communication with devices in safe area, it is necessary to use PFB485EX protective barrier.) |
| BTH-IECEX | Built-in Bluetooth 4.2 (BLE) interface for hazardous area. Maximum communication distance 10 m. Available only for DFWIECEX indicators. Installation service included. |
Digital Input / Output
| Code | Description |
| PPVEX | 3/2-way, Piezo-pilot, overlapping, normally closed (NC) poppet valve. Compatible with DFWIECEX digital outputs. Conforms to ATEX directive. Degree of protection: Gas: II 1G Ex ia IIC T4/T5/T6 Ga. |
| PPVIECEX | 3/2-way, Piezo-pilot, superposed, normally closed (NC) poppet valve. Compatible with DFWIECEX digital outputs. Conforms to ATEX directive and IECEx certification scheme. Degree of protection: Gas: II 1G Ex ia IIC T6 or T4 Ga and Dust: II 1D Ex ia IIIC T135°C. |
| IECEXANOUT | (S1) Intrinsically safe integrated analog output board, 4..20mA, 0..10Vdc |
Power supply
| Code | Description |
| IECEXPW | (S6) IECEx and ATEX power supply for DFWIECEX with 110-230Vac input.
Includes input cable for connection to the network (6m) and output cable for connection to the indicator (3m).
Protection: Ex II 2(2)G Ex q [ib Gb] IIC T4 Gb X for gas and Ex II 2(2)D Ex tb [ib Db] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Please refer to the instruction manual for more information. A printout of the safety instructions and the EU declaration of conformity ATEX (EN, DE, FR, ES, IT) is included. |
| IECEXPW24 | (S6) IECEx and ATEX power supply for DFWIECEX with 24V input (AC or DC).
Includes input cable for connection to the network (6m) and output cable for connection to the indicator (3m).
Protection: Ex II 2(2)G Ex q [ib Gb] IIC T4 Gb X for gas and Ex II 2(2)D Ex tb [ib Db] IIIC T135°C Db X for dust (Ta=0°C/+50°C). Please refer to the instruction manual for more information. A printout of the safety instructions and the EU declaration of conformity ATEX (EN, DE, FR, ES, IT) is included. |
Connection cables
| Code | Description |
| RSCBTW | 4-core twisted shielded cable (2x2x0.34 mm²), for RS485 communication or analogue output. Polyolefin inner sheath. Tinned copper braid shielding. Outer sheath PVC, diameter 7mm. Temperature range: -30 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| EXACB4 | (S6) 4x0.5 mm² armoured cable (suitable for Ex zones). PVC inner sheath. Armour: galvanised steel wire braid. Outer sheath PVC, diameter 7.3 mm. Temperature range: -30 / +80 °C. Minimum bending radius >/= 10 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| EXCB6 | (S6) Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| LCCB a> | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| LCCBA | Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| CB10P | Shielded cable 10x0.25 mm² (suitable for Ex zones). PVC sheath, diameter 7.5mm. Temperature range: -25 / +70 °C (fixed installation). Minimum bending radius >/= 8 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
Support brackets
| Code | Description |
| EXSTFR | AISI 304 stainless steel bracket, adjustable inclination. For mounting IECEX weight indicators on the wall. |
| EXSTFI | AISI 304 stainless steel wall bracket. For mounting IECEX weight indicators. |
ATEX 2GD Remote Button Control
| Code | Description |
| EXPHBN | EX 2GD hand control with 2 buttons and cable gland (optional connection cable). Protection II 2G Ex db eb IIC T6 Gb for gases, II 2D Ex tb IIIC T80°C Db for dust. |
| EXACB4 | (S6) 4x0.5 mm² armoured cable (suitable for Ex zones). PVC inner sheath. Armour: galvanised steel wire braid. Outer sheath PVC, diameter 7.3 mm. Temperature range: -30 / +80 °C. Minimum bending radius >/= 10 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
Approval for sale to third parties
| Code | Description |
| KCEM a> | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
| ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET €. |
| ECEM-AU | Single platform/scale legal-for-trade approval for Australia. |
PC Softwares
| Code | Description |
| D-API a> | Software for recording weighing results to a PC (for internal use) with an integrated API library for interfacing with other software. |
Declaration of ATEX conformity
| Code | Description |
| EXDC | Declaration of ATEX conformity of the assembly. Ex II 2G IIC T4 Gb X and Ex II 2D IIIC T135°C Db X system (Ta=0°C/+40°C), with relative label of whole system, for Dini Argeo DFWIECEX weight indicator connected a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
Optional fixing bracket for indicator
| Code | Description |
| PANEL-ST | Bracket for mounting the indicator on the panel. |
Protection barrier
| Code | Description |
| PFB485EX | Protection barrier for RS485, for direct connection in safe area. Max cable length: 200m. |
| ZBINST | Installation of the ZBA1S / PFB485EX zener barrier inside the indicator case. Note: The cable (LCCB for barrier ZBA1S, RSCBTW for barrier PFB485EX) of the desired length must also be purchased. NET PRICE. |
| RSCBTW | 4-core twisted shielded cable (2x2x0.34 mm²), for RS485 communication or analogue output. Polyolefin inner sheath. Tinned copper braid shielding. Outer sheath PVC, diameter 7mm. Temperature range: -30 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
| PFANOUTEX | Protection barrier for analog current output, 0...20mA or 4...20mA configuration, for direct connection in safe area. Max cable length: 200m.
It requires an external 24Vdc power supply. |
| PFANOUTEXPW | 24Vdc power supply for PFANOUTEX protective barrier. |
PG cable glands
| Code | Description |
| PG7-IECEX | PG7 Cable Gland for DFW and 3590 IECEx Series Cable diameter: 4 to 7 mm. |
| PG9-IECEX | PG9 Cable Gland for DFW and 3590 IECEx Series Complete with ferrules and seals. Cable diameter: 4 to 7 mm or 7 to 10 mm. |
| PG13-IECEX | PG13 Cable Gland for DFW and 3590 IECEx Series Complete with ferrules and seals. Cable diameter: 5,5 to 8 mm, 8 to 10,5 mm or 10,5 to 13 mm. |
Pdf product page
All the specifications and images can be subject to variations and upgrades without prior notice.
|
|