Weight indicators
|
3590EGT-IECEX3GD "TOUCH" : TOUCH SCREEN INDICATOR FOR Ex 2 & 22 ZONES
|
3590EGT-IECEX3GD "TOUCH" : TOUCH SCREEN INDICATOR FOR Ex 2 & 22 ZONES
|
|
|
|
Weight indicator with a big touch screen display, for ATEX 2 & 22 hazardous zones. ATEX/IECEX marking: II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gases II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. ATEX/IECEX marking with intrinsically safe connection for load cells: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gases. II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Suitable for advanced industrial applications, it's fitted with 3 serial ports, Ethernet communication port, configurable printouts and integrated alibi memory. CE-M approvable (OIML R-76 / EN 45501). |  |  | TECHNICAL FEATURES |
|  | - 5,7' colour touch screen display.
- Multilanguage software.
- 15-key alphanumerical waterproof keyboard.
- 3-way control light.
- Selectable QWERTY, AZERTY or QWERTZ keyboard integrated in the touch screen.
- Stainless steel waterproof enclosure, with new IP68 protection system.
- Dimensions: 280x143x185mm.
- Suitable for use on the table, column or wall.
- Real time clock and permanent data storage.
- Alibi memory as standard, integrated on the motherboard.
- Slot for built-in micro SD to record the configuration, logos, and customized screens (upon request).
- Functions available with DINITOOLS utility
- Configuration, data entry and print formatting. - Recording and filing of all the information on PC. - Complete retrieval of the configuration. - Instrument calibration with numeric values. - Customization of the screens. - 24-bit A/D converter, 4 channels, up to 3200 conv./sec. with automatic frequency selection and up to 8 signal linearisation points.
- 4 independent analogue channels for weight reading (up to 2 in E-AF03 version).
- Connection with up to 16 analogue load cells of 350 Ohm (45 load cells of 1000 Ohm).
- Up to 10.000e OIML or multi-range 3 x 3000e @ 0,3 µV/d CE-M legal for trade.
- Up to 1.000.000 displayable divisions for internal factory use, with internal resolution up to 3.000.000 points.
- Connectable to printers and labellers with free programming of the printout formats.
- Power supply from 110-240Vac line or 12-24 Vdc Max. 25.2W
|
 |  |  | I/O SECTION |
|  | - 1 Internal serial ETHERNET port, for connection to the company computer system (excludes a serial port).
- 2 RS232 serial ports on terminals, for connection to printer, PC, radio module and optional interfaces.
- 1 RS485/RS232 serial port on terminals, for connection to weight repeater,remote scale, badge readers or digital load cells.
- 4 serial optoisolated outputs, up to 16 with optional board.
- 2 serial optoisolated inputs, up to 8 with optional board.
- Profibus or Modbus/TCP interface to install in safety zone.
- External Profinet, Ethernet/IP, EtherCAT, CANopen and DeviceNet interface to install in safety zone. (optional, only with standard AF01 weighing program).
- Modbus RTU Interface.
- Optional Bluetooth connection, for fast wireless programming of archives, via PC, tablet or smartphone.
- Analog output DAC16O requires IOEXPB expansion board.
|
|
|
Available versions
| Code | Description |
 | 3590EGT-IECEX3GD | Ex colour Touch Screen indicator for zone 2/22 with AF01 software. IP68 stainless steel enclosure. ATEX/IECEX II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
 | 3590EGT-IECEX3GDZB | Ex colour Touch Screen indicator for zone 2/22 with AF01 software, connectable directly to load cells installed in zone 1/21 and 0/20. IP68 stainless steel enclosure. ATEX/IECEX marking: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
Available firmwares
| Code | Description |
 | AF01 a> | Software for totalization and formula weighing. |
 | AF02 a> | Software for piece/quantity counting. |
 | AF03GT a> | Software for weighbridges, vehicle In/Out. For 3590 "TOUCH SCREEN" weight indicators. |
 | AF04GT a> | Software for statistical checking of prepackaged goods. For 3590 "TOUCH SCREEN" weight indicators. |
 | AF05 a> | Software for price computing and industrial labelling. |
 | AF08 a> | Software for static wheel and axle weighing with 2 or more pads. |
 | AF09 a> | Software for dynamic and static axle weighing with 1 or 2 pads. |
 | BATCH1 a> | Software for single product dosage systems in loading and unloading. |
 | BATCH a> | Software for multicomponent dosage systems in loading and unloading. NOTE: For 3590, IOEXPB expansion board is required. |
Optional power supply cords
| Code | Description |
 | EXACB4 | (S6) Armoured 4x0,5mm² cable, for Ex systems. €/m |
Declaration of ATEX conformity
| Code | Description |
 | DCATEX3GD | Declaration of ATEX conformity of whole. Ex II 3G IIC T6 Gc X and Ex II 3D IIIC T115°C Dc X system, with relative label of whole system, for ATEX certified or NOT ATEX certified Dini Argeo indicator (in the latter case to be installed in a safe area) connected to a mechanical structure with ATEX load cells (each load cell must be certified with CCATEX or CCATEX3GD option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN, DE, FR, ES and IT). |
 | DCATEXMB4 | ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125°C Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
(*) DCATEXMB4 compatible only with 3590EGT-IECEX3GDZB.
Approval for sale to third parties
| Code | Description |
 | KCEM a> | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
| ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET €. |
Printers/Labellers for safe zones
| Code | Description |
 | OBTPRB a> | (S1) Table thermal printer. For weight indicator, with IP40 ABS case, 1,5 m connection cable and internal power supply. |
 | LP542S a> | (S1) Direct thermal labeller. |
 | SMTPLUS-1 a> | (S1) Thermal transfer or direct termal labeller. Peel-off kit in option. |
 | SMTRPK-1 | (S1) Label peel-off and rewind kit for SMTPLUS-1 labeller. |
 | PRNSERV | Custom-made ticket (up to 4 layouts). NET price. |
 | APRNSERV | Custom-made label (up to 4 layouts). NET price. |
Connection cables
| Code | Description |
 | RSCBTW | Cable of 2 twisted pairs (€/metre). Double screening for RS422–RS485 connections. 10m minimum length |
Storing the weighs
| Code | Description |
 | SWM a> | "WeiMonitor" PC program to monitor and record in real time weighs performed on the connected scale (the price is intended for the license to manage one scale). |
Software for display customisation
| Code | Description |
 | DDT | Software for the quick customisation of the touchscreen display. For 3590ET and 3590EGT series indicators. |
Communication Interfaces
| Code | Description |
 | RFITR-1 a> | (S1) Built-in 868 MHz radiofrequency module. Max. functioning distance in appropriate environmental and installation conditions: 70m indoors, 150m outdoors. Up to 50 configurable channels.(RFITR must be combined with another radio module). |
 | WIFITD-2 a> | (S1) Built-in WI-FI interface. For wireless connection (through access point) to the company computer system. |
 | PROFI232-1 a> | External RS232/RS485/PROFIBUS interface for DIN bar. Connectable to the indicators with Profibus protocol with PCB, terminal blocks, plastic box and UL-marked labels (if applicable). |
 | BLTH-2 a> | (S1) Built-in bluetooth interface. For wireless connection of the scale to tablets, smartphones or laptops. Weighing apps downloadable from Google Play. |
Fieldbus interfaces
| Code | Description |
 | PROFINET1S a> | RS485 to ProfiNET interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
 | ETHERNETIP1S a> | RS485 to Ethernet IP interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
 | ETHERCAT1S a> | RS485 to EtherCAT interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
 | DEVICENET1S a> | RS485 to DeviceNET interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
 | CANOPEN1S a> | RS485 to CANOPEN interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
NOTE: compatible only with standard AF01 weighing programme
Display customisation
| Code | Description |
 | GTMEM | 10 memories set for display customization with logos and images. |
Digital Input / Output
| Code | Description |
 | IOEXPB | (S1) Built-in board with 12 OUT and 6 IN (mounting and cable gland excluded). It includes expansion circuit of the power supply range of the indicator (8-40Vdc). NOT COMPATIBLE WITH 3590E4CH AND TPRXT. With UL marked PCB, Terminal block, plastic box and labels (if applicable). |
 | DAC16O-1 | (S1) Built-in analog output, 0-4/20 mA, 0-10VdC (cable gland excluded). For DFW, 3590 and CPW indicators. NOTE: For 3590, only with IOEXPB optional board. This interface is not available on its own, always to be combined with a weight indicator when ordering. |
Other options
| Code | Description |
| TECSUP | Technical assistance by telephone upon request. |
All the specifications and images can be subject to variations and upgrades without prior notice.
|
|