MBA: kit of zener barriers for hazardous areas.

KIT of three intrinsic protection zener barriers, for connection of devices en ATEX area with devices in safe area. Suitable for mounting on a panel board on an omega bar in a safe area, or in a hazardous-proof case, for intrinsic safety weighing systems in hazardous area. Marking of single barrier: Ex II (1) GD [Ex ia] IIC [Ex iaD].
 SINGLE CHANNEL FEATURES
  • Barrier for output:
    Fuse: 50mA
    Uo: 8.7 Vdc
    Io: 25mA
    Po: 0,05W
    Co: 4,9µF
    Lo: 57mH
    L/R: 613µH/Ω
    Rmin: 352,8Ω

  • Barrier for sense:
    Fuse: 50mA
    Uo: 8.7 Vdc
    Io: 25mA
    Po: 0,05W
    Co: 4,9µF
    Lo: 57mH
    L/R: 613µH/Ω
    Rmin: 352,8Ω

  • Barrier for input:
    Fuse: 100mA
    Uo: 12Vdc
    Io: 164mA
    Po: 0,49W
    Co: 1,41µF
    Lo: 1,38mH
    L/R: 75µH/Ω
    Rmin: 73,5Ω

  • NOTE: connection with up to 4 load cells of 350 ohm each.

Available versions:
 CodeDescription 
MB4Kit of 3 passive safety zener barriers for up to 4 load cells of 350 ohm each, suitable for mounting on a panel board on an omega bar in a safe area, or in a hazardous-proof case, for intrinsic safety weighing systems in hazardous area. LCCB cable max length of 50 m. Marking of single barrier: Ex II (1) GD [Ex ia] IIC [Ex iaD].

Options only available at time of order:
 CodeDescription 
DCATEXMB4Declaration of ATEX conformity of the whole, Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for NON ATEX weight indicator connected to MB4 Dini Argeo zener barriers, connected to mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). ATEX CONFORMITY DECLARATIONS will be supplied in English.