"WBSA APPROVED" series MODULAR TYPE "AMERICA" WEIGHBRIDGES





"WBSA APPROVED" series MODULAR TYPE "AMERICA" WEIGHBRIDGES


  "WBSA APPROVED" series MODULAR TYPE "AMERICA" WEIGHBRIDGES
 

Modular new generation weighbridges, for installation flush floor to the road surface. Suitable in industrial, agricultural, and commercial fields. The standard version is fitted with CE-M 3000+3000e APPROVAL.

MAIN FEATURES

  • Bearing structure formed by reinforced steel beams.
  • Sturdy load surface in very thick antislip sheet steel, which guarantees extreme rigidity with every type of vehicles.
  • Anticorrosive treatments and high-resistance painting.
  • Double shear-beam IP68 load cells, C3 precision class, EN45501 approved, complete of spherical selfcentering oscillating joints, for compensating the thermal expansions, guaranteeing safe weighs and long term accuracy.
  • The load capacity complies with the 96/53/EC Directive which defines the maximum axle load for the vehicles transiting in Europe (version for higher loads is available upon request).
  • Inspected trapdoors for cells maintenance.
  • Reduced height (up to 370 mm from the resting surface).
  • IP68 junction box, complete of 30m connection cable to the indicator.
  • Dual range 3000 + 3000e CE-M approval.
  • Wide range of available weight indicators and accessories.
OPTIONS AND ACCESSORIES
  • Angles' kit for flush floor installation.
  • 3GD and 2GD ATEX versions upon request.
DOWNLOAD
Available versions
 
Code
Classl x w x h
(m)
Nr. of cellsMax
(kg)
WBS9-RCPTD-C4C49 x 3 x 0,376 x 30000kg50000
WBS14-RCPTD-C4C413,5 x 3 x 0,378 x 30000kg60000
WBS18-RCPTD-C4C418 x 3 x 0,3710 x 30000kg60000
 CodeDescription
WBTRASP2 Transport costs for weighing system up to 18 metres long. Ask for price estimate.
Kit for installing on the street surface
 CodeDescription
WB9TF Angles' kit for WBSAA with 9x3m plate. NET €
WB14TF Angles' kit for WBSAA with 13,5x3m plate. NET €
WB18TF Angles' kit for WBSAA with 18x3m plate. NET €
Connection cables
 CodeDescription
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m
LCCBA Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m

Pdf product page All the specifications and images can be subject to variations and upgrades without prior notice.