Tension





STG SERIES TENSION LOAD CELLS


  STG SERIES TENSION LOAD CELLS
 

ATEX VERSION
  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
    ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Tension or Compression approved load cells for the weighing hoppers, tanks, scales with levers, and with other weighing devices.

CAPACITIES (kg): 100, 500, 1000.

OIML R60. C3 precision class.

17-4 PH stainless steel. IP67 protection.

MAIN FEATURES

  • C3 PRECISION CLASS
  • 17-4 PH STAINLESS STEEL CONSTRUCTION
  • IP67 PROTECTION
  • MAX. CAPACITIES FROM 100 TO 1000 kg
  • SHIELDED CONNECTION CABLE
  • TEST CERTIFICATE AVAILABLE UPON REQUEST

TECHNICAL FEATURES

  • Minimum load cell verification interval:
    Vmin = EMax / 10.000 (for STG500 and STG1000 model);
    Vmin = EMax / 7.000 (for STG100 model)
  • Maximum number of verification intervals: nLC = 3000
  • Combined error 0,03% of Full Scale Output (F.S.)
  • Non-Repeatability: 0,01% F.S.
  • Full Scale Output: 3mV/V +/- 0,08%
  • Temperature effect on zero: 0,017% /°C
  • Temperature effect on full scale output: 0,014% /°C
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -35°C/+65°C
  • Creep error after 30 minutes: 0,02% F.S.
  • Maximum tolerated excitation voltage: 18 VDC
  • Input Resistance: 430 ± 60 Ohm
  • Output Resistance: 350 ± 3.5 Ohm
  • Zero balance: +/-1% F.S.
  • Insulation Resistance: >5000 MOhm
  • Safe Overload: 150% F.S.
  • Ultimate Overload: 300% F.S.
  • 4-wire shielded cable, 6m long, 5 mm diameter
DOWNLOAD
Available versions

Code
Max
(kg)
STG100100
STG500500
STG10001000
Assembly kits
 CodeDescription
RBJM8 M8 articulated rod-end ball joint. Maximum lifting capacity of 600kg. For STG100.
RBJM12 M12 articulated rod-end ball joint. Maximum lifting capacity of 1000kg. For STG500 and STG1000.
CLVM8 M8 clevis fitted with pin, for combination with RBJM8. For STG100.
CLVM12 M12 clevis fitted with pin, for combination with RBJM12. For STG500 and STG1000.
Options for ATEX version
 CodeDescription
ZBA1S Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a hazardous-proof case. Marking: ATEX II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC.
KZBA ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in an explosive zone. Dimensions 180x180x150mm.Can connect up to 4 Load Cell of 350 Ohm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C) for dust.
JB4QAI Stainless steel IP66, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
JB4QA ABS IP67, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
EXCB6(S6) Shielded, blue, 6x0,22mm² cable, for EX i (2GD) applications. €/m
KMB4 Kit of 3 ATEX zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in an hazardous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts.
CCATEX-1 Optional ATEX version for single load cell. Categories: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Complete with manual and ATEX EU CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
DCATEXMECH DCATEXMECH: ATEX declaration for the PLATFORM / LOAD CELL ASSEMBLY KIT (for the load cells ATEX declaration see CCATEX-1 code). Option to be offered only if the platform is ordered without the indicator, if so, refer to the chosen weight indicator available certifications.
DCATEXMB4 ATEX declaration of the whole for systems with zener barriers. Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option).

All the specifications and images can be subject to variations and upgrades without prior notice.