Tension





STG SERIES TENSION LOAD CELLS


  STG SERIES TENSION LOAD CELLS
 
  • Wiring Code
    Colour
    Function
    RED
    INPUT +
    BLACK
    INPUT -
    GREEN
    OUTPUT +
    WHITE
    OUTPUT -
    METAL
    SHIELD
ATEX VERSION
  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
    ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Tension or Compression approved load cells for the weighing hoppers, tanks, scales with levers, and with other weighing devices.

CAPACITIES (kg): 100, 500, 1000.

OIML R60. C3 precision class.

17-4 PH stainless steel. IP67 protection.

MAIN FEATURES

  • C3 PRECISION CLASS
  • 17-4 PH STAINLESS STEEL CONSTRUCTION
  • IP67 PROTECTION
  • MAX. CAPACITIES FROM 100 TO 1000 kg
  • SHIELDED CONNECTION CABLE
  • TEST CERTIFICATE AVAILABLE UPON REQUEST

TECHNICAL FEATURES

  • Minimum load cell verification interval:
    Vmin = EMax / 10.000 (for STG500 and STG1000 model);
    Vmin = EMax / 7.000 (for STG100 model)
  • Maximum number of verification intervals: nLC = 3000
  • Combined error 0,03% of Full Scale Output (F.S.)
  • Non-Repeatability: 0,01% F.S.
  • Full Scale Output: 3mV/V +/- 0,08%
  • Temperature effect on zero: 0,017% /°C
  • Temperature effect on full scale output: 0,014% /°C
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -35°C/+65°C
  • Creep error after 30 minutes: 0,02% F.S.
  • Maximum tolerated excitation voltage: 18 VDC
  • Input Resistance: 430 ± 60 Ohm
  • Output Resistance: 350 ± 3.5 Ohm
  • Zero balance: +/-1% F.S.
  • Insulation Resistance: >5000 MOhm
  • Safe Overload: 150% F.S.
  • Ultimate Overload: 300% F.S.
  • 4-wire shielded cable, 6m long, 5 mm diameter
DOWNLOAD
Available versions
 
Code
Max
(kg)
STG100 100
STG500 500
STG1000 1000
Assembly kits
 CodeDescription
RBJM8 M8 articulated rod-end ball joint. Maximum lifting capacity of 600kg. For STG100 and SL up to 50kg capacity.
RBJM12 M12 articulated rod-end ball joint. Maximum lifting capacity of 1000kg. For STG500, STG1000 and SL capacity from 100 to 1000kg.
CLVM8 M8 clevis fitted with pin, for combination with RBJM8. For STG100 and SL capacity up to 50kg.
CLVM12 M12 clevis fitted with pin, for combination with RBJM12. For STG500, STG1000 and SL capacity from 100 to 1000kg.
Options for ATEX version
 CodeDescription
ZBA1S Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
KZBA-1 ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135°C Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT).
JB4QAI ATEX equalisation box made of stainless steel IP66 for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
JB4QA ATEX equalisation box made of ABS IP67, for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
EXCB6(S6) Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m
KMB4-1 Kit of 3 ATEX Zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in a dangerous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT).
CCATEX-1 Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
CCATEX3GD ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115°C Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT).
DCATEXMECH ATEX version for the PLATFORM / LOAD CELL MOUNTING KIT for zone 1/21 (for the load cells ATEX declaration see CCATEX code). Option to be offered only if the platform is ordered without the indicator, otherwise refer to the available certifications for the chosen weight indicator. Provided with safety instructions and ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
DCATEXMB4 ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125°C Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT).

Pdf product page All the specifications and images can be subject to variations and upgrades without prior notice.
ASSISTANCE
DOCUMENTS
SALES NETWORK
CATALOGS