Crane scales, weighing systems, pallet trucks, weigh bridge, indicators, load cells
 
SPH SERIES SINGLE POINT LOAD CELLS

  SPH SERIES SINGLE POINT LOAD CELLS
 

Dimensions (mm)

Wiring Code

Colour

Function

  --

SHIELD

YELLOW

OUTPUT +

GREY

SENSE +

BROWN

INPUT +

WHITE

OUTPUT -

GREEN

INPUT -

PINK

SENSE -



Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell.
 MAIN FEATURES
  • C3 PRECISION CLASS
  • OFF CENTER LOAD COMPENSATED
  • ALUMINIUM ALLOY CONSTRUCTION
  • IP65 PROTECTION
  • CAPACITIES FROM 50 TO 200 kg
  • FOR PLATFORMS WITH DIMENSIONS UP TO 500 X 500 mm
  • SHIELDED CONNECTION CABLE
  • OIML CERTIFICATE AVAILABLE UPON REQUEST
  • TEST CERTIFICATE AVAILABLE UPON REQUEST
 TECHNICAL FEATURES
  • Minimum load cell verification interval: Vmin = EMax / 10.000
  • Maximum number of verification intervals: nLC = 3000
  • Full Scale Output: 2mV/V +/- 10%
  • Combined error: 0,017% of Full Scale Output (F.S.)
  • Temperature effect on zero: 0,0028% /°C
  • Temperature effect on full scale output: 0,0014% /°C
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -20°C/+60°C
  • Creep error after 20 minutes: 0,025% F.S.
  • Maximum tolerated excitation voltage: 15 VDC
  • Input Resistance: 410 ±20 Ohm
  • Output Resistance: 350 ± 5 Ohm
  • Zero Balance: +/-10% F.S.
  • Insulation Resistance: >1000 MOhm
  • Safe Overload: 150% F.S.
  • Ultimate Overload: >200% F.S.
  • Nominal displacement: < 0.8 mm
  • 6-wire shielded cable, 3m long, 5mm diameter
 EXTRAS AVAILABLE (at time of order)
  • OIML R60 certificate (without surcharge)
  • II 1GD ATEX Certificate for each load cell (with surcharge)
  • Declaration of ATEX conformity of the system (for the code see the pages of the atex weight indicators and MB4 atex barrier kit)
Available models
 CodeMax Capacity kgPlatform mmMasterpack
4 pcs
 SPH50 50500x500SPH50C
 SPH100 100500x500SPH100C
 SPH200 200500x500SPH200C

Certification
 CodeDescription 
DCATEXMB4Declaration of ATEX conformity of the whole, Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for NON ATEX weight indicator connected to MB4 Dini Argeo zener barriers, connected to mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). ATEX CONFORMITY DECLARATIONS will be supplied in English.
CCATEXATEX certificate for each load cell for the following categories: II 1G EExia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) and II 1D tD A20 TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C). Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
Dini Argeo S.r.l. P.IVA/VAT IT00767800360 - Copyright 2011 - All Rights Reserved - Privacy Policy www.diniargeo.com