Compression





CP SERIES LOW PROFILE LOAD CELLS


  CP SERIES LOW PROFILE LOAD CELLS
 
ATEX VERSION
  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
    ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Stainless steel compression load cells suitable for weighing tanks and hoppers with the relevant accessories.

CAPACITIES (kg): 250, 500, 1000, 2500, 5000, 7500, 10000, 15000, 30000, 50000, 100000.

Stainless steel. IP68 protection. C3 precision class.

MAIN FEATURES

  • LOW PROFILE
  • STAINLESS STEEL CONSTRUCTION
  • IP68 PROTECTION
  • MAX. CAPACITIES FROM 250 TO 100000 kg
  • SHIELDED CONNECTION CABLE

TECHNICAL FEATURES

  • Full Scale Output: 2mV/V +/- 0,5%
  • Non-Repeatability: 0,01% F.S.
  • Temperature effect on zero: 0,02% / 10°C
  • Temperature effect on full scale output: 0,02% / 10°C
  • Compensated Temperature Range: -10°C/+50°C
  • Operating Temperature Range: -20°C/+60°C
  • Creep error after 30 minutes: 0,02% F.S.
  • Recommended excitation voltage: 10 Vdc
  • Maximum tolerated excitation voltage: 15 Vdc
  • Input Resistance: 750 ± 10 Ohm
  • Output Resistance: 700 ± 5 Ohm
  • Zero Balance: +/-1% F.S.
  • Insulation Resistance: >5000 MOhm
  • Safe Overload: 120% F.S.
  • 4-wire shielded cable, 5 mm diameter:
    - 5 m long for CP 250...5000 versions;
    - 10 m long for CP 7500...100000 versions.

    Wiring Code
    Colour
    Function
      --
    SHIELD
    GREEN
    OUTPUT +
    RED
    INPUT +
    WHITE
    OUTPUT -
    BLACK
    INPUT -
DOWNLOAD
Available versions

Code
Max
(kg)
CP250250
CP500500
CP10001000
CP25002500
CP50005000
CP75007500
CP1000010000
CP1500015000
CP3000030000
CP5000050000
CP100000100000
Assembly kits
 CodeDescription
KCPN10A Nickel steel kit for assembling a CP/CPX cell, up to 12500kg. (Load cell not included)
Assembly kits
 CodeDescription
KCPN10 Stainless steel kit for assembling a CP/CPX cell, up to 12500kg. (Load cell not included)
KCPN15 Stainless steel kit for assembling a 15000kg CP/CPX cell. (Load cell not included)
KCPN30 Stainless steel kit for assembling a 30000kg CP/CPX cell. (Load cell not included)
KCPN100 Stainless steel kit for assembling a CP/CPX cell from 50000 to 100000kg. (Load cell not included)
Assembly kits
 CodeDescription
ELGOC Multipurpose plate with screws. For CP/CPX load cells up to 12.500kg.
ELGOP Fixing plate with screws. For CP/CPX load cells up to 12.500kg.
ELGON Load button to be combined with ELGOC for applications including dummy load cells.
Stay rod
 CodeDescription
LNK2635 Galvanized stay rod with ball-and-socket joints. Max 100 kN.
LNKST Mounting kit for stay rod. Fitted with fixing screw.
Connection cables
 CodeDescription
LCCB Shielded 6x0,25 mm² cable (suitable for Ex zones). €/m
LCCBM Shielded 4x0,34mmq cable for moving applications. €/m
PRCB Protection sheathing for shielded cable. €/meter
Junction Boxes
 CodeDescription
JB4Q Equalisation box for connection with up to 4 load cells. ABS box, IP67 protection degree, with 4 + 1 fairleads.
JB4Q Equalisation box for connection with up to 4 load cells. ABS box, IP67 protection degree, with 4 + 1 fairleads.
JB4QI Stainless steel equalisation box for connection with up to 4 load cells. IP65 protection degree, with 4 + 1 fairleads.
JC4Q Equalisation board for up to 4 cells.
Available weight indicator/transmitter
 CodeDescription
DGT1 Weight transmitter for DIN bar. 5-key keypad, LED display, real time clock, alibi memory, and multifunction weighing programme.
DGT1S Weight transmitter on DIN bar, with 2 INPUTS and 2 OUTPUTS. Fitted with 5-key keypad and LED display. Multifunction weighing program.
DGT4 Transmitter for DIN bar with 4 channels, 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing programme.
DGTQ Transmitter for panel mounting, with 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing programme.
Options for ATEX version
 CodeDescription
ZBA1S Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a hazardous-proof case. Marking: ATEX II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC.
KZBA ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in an explosive zone. Dimensions 180x180x150mm.Can connect up to 4 Load Cell of 350 Ohm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C) for dust.
JB4QAI Stainless steel IP66, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
JB4QA ABS IP67, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
EXCB6(S6) Shielded, blue, 6x0,22mm² cable, for EX i (2GD) applications. €/m
LCCB Shielded 6x0,25 mm² cable (suitable for Ex zones). €/m
KMB4 Kit of 3 ATEX zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in an hazardous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts.
CCATEX-1 Optional ATEX version for single load cell. Categories: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Complete with manual and ATEX EU CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
DCATEXMECH DCATEXMECH: ATEX declaration for the PLATFORM / LOAD CELL ASSEMBLY KIT (for the load cells ATEX declaration see CCATEX-1 code). Option to be offered only if the platform is ordered without the indicator, if so, refer to the chosen weight indicator available certifications.
DCATEXMB4 ATEX declaration of the whole for systems with KMB4 barriers. Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for weight indicators connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option).

All the specifications and images can be subject to variations and upgrades without prior notice.
ASSISTANCE
DOCUMENTS
SALES NETWORK
CATALOGS