Analog





RICE LAKE CANISTER LOAD CELL, IN STAINLESS STEEL, “RL5426” SERIES


  RICE LAKE CANISTER LOAD CELL, IN STAINLESS STEEL, “RL5426” SERIES
 
  • CONNECTION



    Cable Color Code
    RED
    INPUT +
    BLACK
    INPUT -
    VERDE
    OUTPUT +
    WHITE
    OUTPUT -
    YELLOW
    SENSE +
    BLUE
    SENSE -
    METAL
    Shield

  • INSTALLATION KIT


  • The 173793 kit allows a correct installation of the RL5426 load cells below the weighbridge plate.
  • The kit consists of an upper cup and a lower cup with anti-rotation system. All components are made from stainless steel. Both cups are designed for optimal operation in conjunction with the cell’s self-centring spherical bases, allowing their proper oscillation and return to position.
Canister load cells for CE-M approved weighbridges, tanks, silos, etc. Manufactured in STAINLESS STEEL, IP69K protection degree, 6000 divisions.

CAPACITIES: 20 t, 30 t, 40t, 50 t.

OIML R60. C6 precision class.

Stainless steel body. IP69K Protection Degree.

20 m Cable.

h= 118,5 mm.

  • TECNICAL FEATURES


    METROLOGICAL FEATURES

  • Rated capacity: (FS): 20t, 30t, 50t
  • Combined error: 0,02 %F.S
  • Creep error (after 30 min.): 0,02 %FS
  • Temperature effect on zero: 0,003 %F.S./°C
  • Temperature effect on sensitivity: 0,0008 %F.S./°C

    OIML R60

  • Vmin= Emax/18000
  • Accuracy class: C6
  • Max. number of intervals: 6000e OIML

    ELECTRONIC\MECHANICAL FEATURES

  • Gas dischargers to protect against atmospheric discharges
  • Power Supply: 5...15 Vdc
  • Rated output at F.S.: 2 ± 0.1% mV/V
  • Input resistance: 800 ± 3Ω
  • Output resistance: 700 ± 3Ω
  • Insulation resistance: 5000MΩ
  • Operating temperature: -20 ~ +70 °C
  • Compensated temperature for homologation: -10 ~ +40 °C
  • Storage temperature limits: -40° ~ +80°
  • Safe load limit: 120% F.S.
  • Ultimate overload: 150% F.S.
  • IP69K protection degree
  • Stainless steel body
  • 6-core cable, l= 20 m
  • Nickel plated steel cable gland
  • Self-centring spherical bases
  • Equipped with anti-rotation system, to be combined with 173798 cups for proper operation
DOWNLOAD
Available versions
 
Code
Max
(kg)
177961 20 000
177963 30 000
177965 40 000
177967 50 000
Assembly kits
 CodeDescription
173798 Kit of 2 jointed cups for selfalignment, in stainless steel. For RL5426xx load cells.
Junction Box / Boards - Cell cables
 CodeDescription
JB10Q Equalisation box for connection with up to 10 analogue load cells. Reinforced polyester box, with 10 + 1 fairleads. With surge arresters, PCB, Terminal block, plastic box and UL marked labels (if applicable).
LCCB Shielded 6x0,25 mm² cable (suitable for Ex zones). €/m
Protection for junction box/electronic circuits
 CodeDescription
GELBOX(S1) Anti condensation, insulating, and sealing gel. Useful to protect the electronic circuits of the weighing system, even under prolonged immersions conditions. Pack of 300ml.
WARNING:
For JB10Q/JB10QD: 1200ml of gel required

All the specifications and images can be subject to variations and upgrades without prior notice.