Column, for Weighbridges





"RCPT" ANALOG LOAD CELL SERIES


  "RCPT" ANALOG LOAD CELL SERIES
 

RCPT: steel load cell, for high capacity weighing systems.


RCP: dimensions in mm.

Compression load cell for CE-M approved weighbridges, tanks, silos, etc. Completely manufactured in steel, and fitted with selfaligned articulated joints, selfcentering plates and protection washer.

CAPACITIES (kg): 20000, 30000, 50000.

OIML R60. C3 precision class.

Internal stainless steel with alloy steel body. IP68 protection.

MAIN FEATURES

  • C3 PRECISION CLASSES.
  • INNER STAINLESS STEEL with SPECIAL ALLOY STEEL BODY; MANUFACTURED WITH LASER SOLDERINGS.
  • OPTIMISED FOR PARALLEL CONNECTION.
  • IP68 PROTECTION DEGREE.
  • CAPACITY FROM 20000 TO 50000 kg.
  • FITTED WITH SELF-ALIGNED ARTICULATED JOINTS, SELFCENTERING PLATES AND PROTECTION WASHER.
  • SHIELDED 15m CONNECTION CABLE.
  • TEST CERTIFICATE AVAILABLE UPON REQUEST.

TECHNICAL FEATURES

  • Minimum load cell verification interval: Vmin = EMax / 10.000
  • Maximum number of load cell divisions: nLC = 3000 (C3)
  • Sensitivity: 2mV/V +/- 0,1%
  • Temperature effect on full scale: 0,002% /°C
  • Temperature effect on zero: 0,002% /°C
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -30°C/+70°C
  • Creep error after 30 minutes: 0,02% F.S.
  • Excitation voltage from 5 to 15 VDC
  • Input Resistance: 700 ± 20 Ohm
  • Output Resistance: 703 ± 7 Ohm
  • Zero Balance: +/-1% F.S.
  • Insulation Resistance: >5000 MOhm
  • Safe Overload: >150% F.S.
  • Ultimate Overload: 250% F.S.
  • 4-wire shielded cable, 14m long, 5mm diameter.

ATEX Version

  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
    ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.

    Wiring Code
    Coluor
    Function
    GREEN
    OUTPUT +
    WHITE
    OUTPUT -
    RED
    INPUT +
    BLACK
    INPUT -
DOWNLOAD
Available versions

Code
Max
(kg)
RCPT20C320000
RCPT30C330000
RCPT50C350000
Junction Box / Boards - Load Cell cables
 CodeDescription
JB10Q Equalisation box for connection with up to 10 analogue load cells. Reinforced polyester box, with 10 + 1 fairleads.
LCCB Shielded 6x0,25 mm² cable (suitable for Ex zones). €/m
Options for ATEX version
 CodeDescription
ZBA1S Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a hazardous-proof case. Marking: ATEX II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC.
KZBA ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in an explosive zone. Dimensions 180x180x150mm.Can connect up to 4 Load Cell of 350 Ohm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C) for dust.
JB4QAI Stainless steel IP66, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
JB4QA ABS IP67, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
EXCB6(S6) Shielded, blue, 6x0,22mm² cable, for EX i (2GD) applications. €/m
KMB4 Kit of 3 ATEX zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in an hazardous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts.
CCATEX-1 Optional ATEX version for single load cell. Categories: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Complete with manual and ATEX EU CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
DCATEXMECH DCATEXMECH: ATEX declaration for the PLATFORM / LOAD CELL ASSEMBLY KIT (for the load cells ATEX declaration see CCATEX-1 code). Option to be offered only if the platform is ordered without the indicator, if so, refer to the chosen weight indicator available certifications.
DCATEXMB4 ATEX declaration of the whole for systems with KMB4 barriers. Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for weight indicators connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option).

RCPT is fitted with protection washer and selfcentering plates:

RCPT con with washer protecting against
water, mud and dust. 
RCPT with protective washer and
fitted with selfcentering plates.


All the specifications and images can be subject to variations and upgrades without prior notice.
ASSISTANCE
DOCUMENTS
SALES NETWORK
CATALOGS