Bending Beam
|
FXD SERIES BENDING BEAM LOAD CELLS
|
FXD SERIES BENDING BEAM LOAD CELLS
|
|
|
|
Dimensions (mm)
Wiring Code
|
Colour |
Function
|
-- |
SHIELD
|
GREEN |
OUTPUT +
|
RED |
INPUT +
|
WHITE |
OUTPUT -
|
BLACK |
INPUT -
|
|
|
|
Bending beam load cells for approved weighing, automatic systems, dosage.
CAPACITIES (kg): 100, 200, 300, 500.
OIML R60. C3 precision class.
Stainless steel. IP68 protection.
|
|
Available versions
| Code | Max (kg) |
| FXD100  | 100 |
| FXD200  | 200 |
| FXD300  | 300 |
| FXD500  | 500 |
Assembly kits
| Code | Description |
 | KFXDN a> | Stainless steel kit for assembling 1 FXC/FXD cell up to 500kg. (Load cell not included) |
Connection cables
| Code | Description |
 | LCCB a> | Shielded 6x0,25 mm² cable (suitable for Ex zones). €/m |
 | LCCBM a> | Shielded 4x0,34mmq cable for moving applications. €/m |
 | PRCB | Protection sheathing for shielded cable. €/meter |
Junction Boxes
| Code | Description |
 | JB4Q a> | Equalisation box for connection with up to 4 load cells. ABS box, IP67 protection degree, with 4 + 1 fairleads. |
 | JB4Q a> | Equalisation box for connection with up to 4 load cells. ABS box, IP67 protection degree, with 4 + 1 fairleads. |
 | JB4QI a> | Stainless steel equalisation box for connection with up to 4 load cells. IP65 protection degree, with 4 + 1 fairleads. |
 | JC4Q a> | Equalisation board for up to 4 cells. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
Available weight indicator/transmitter
| Code | Description |
 | DGT1S a> | Weight transmitter on DIN bar, with 2 INPUTS and 2 OUTPUTS. Fitted with 5-key keypad and LED display. Multifunction weighing program.
|
 | DGT1 a> | Weight transmitter for DIN bar. 5-key keypad, LED display, real time clock, alibi memory, and multifunction weighing programme. |
 | DGT4 a> | Transmitter for DIN bar with 4 channels, 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing programme. |
 | DGTQ a> | Transmitter for panel mounting, with 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing programme. |
Options for ATEX version
| Code | Description |
 | ZBA1S a> | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a hazardous-proof case. Marking: ATEX II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Manual and ATEX UE CONFORMITY DECLARATIONS (available in EN, DE, FR, ES and IT). |
 | KZBA a> | ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in an explosive zone. Dimensions 180x180x150mm.Can connect up to 4 Load Cell of 350 Ohm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C) for dust. |
 | JB4QAI a> | Stainless steel IP66, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT). |
 | JB4QA | ABS IP67, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT). |
 | EXCB6 | (S6) Shielded, blue, 6x0,22mm² cable, for EX i (2GD) applications. €/m |
 | KMB4 a> | Kit of 3 ATEX zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in an hazardous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts. |
 | CCATEX-1 | Optional ATEX version for single load cell. Categories: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Complete with manual and ATEX EU CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
|
 | DCATEXMECH | DCATEXMECH: ATEX declaration for the PLATFORM / LOAD CELL ASSEMBLY KIT (for the load cells ATEX declaration see CCATEX-1 code). Option to be offered only if the platform is ordered without the indicator, if so, refer to the chosen weight indicator available certifications. |
 | DCATEXMB4 | ATEX declaration of the whole for systems with zener barriers. Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). |
All the specifications and images can be subject to variations and upgrades without prior notice.
|
|