Crane scales, weighing systems, pallet trucks, weigh bridge, indicators, load cells
 
FXC SERIES BENDING BEAM LOAD CELLS

  FXC SERIES BENDING BEAM LOAD CELLS
 

Dimensions (mm)

Wiring Code

Colour

Function

  --

SHIELD

BLACK

OUTPUT +

RED

INPUT +

BLUE

OUTPUT -

WHITE

INPUT -



Bending beam load cells for approved weighing, automatic systems, dosage.
 MAIN FEATURES
  • C3 PRECISION CLASS
  • STAINLESS STEEL
  • IP68 PROTECTION
  • MAX. CAPACITIES FROM 10 TO 500 kg
  • SHIELDED CONNECTION CABLE
  • OIML CERTIFICATE AVAILABLE UPON REQUEST
  • TEST CERTIFICATE AVAILABLE UPON REQUEST
 TECHNICAL FEATURES
  • Minimum load cell verification interval: Vmin = EMax / 10.000
  • Maximum number of verification intervals: nLC= 3000
  • Full Scale Output: 2mV/V +/- 0,1%
  • Combined error: 0,017% of Full Scale Output (F.S.)
  • Non-Repeatability: 0,015% F.S.
  • Temperature effect on zero: +/- 0,002% /°C
  • Temperature effect on full scale output: +/- 0,0012% /°C
  • Compensated Temperature Range: –10°C/+40°C
  • Operating Temperature Range: –20°C/+60°C
  • Creep error after 30 minutes +/- 0,016% F.S.
  • Maximum tolerated excitation voltage: 15 VDC
  • Input Resistance: 385 ± 20 Ohm
  • Output Resistance: 350 ± 5 Ohm
  • Insulation Resistance: > 5000 MOhm
  • Safe Overload: 200% F.S.
  • Ultimate Overload: >300% F.S.
  • Nominal displacement: < 0,4 mm
  • 4-wire shielded cable, 3m long, 4mm diameter.
 EXTRAS AVAILABLE (at time of order)
  • OIML R60 certificate (without surcharge)
  • II 1GD ATEX Certificate for each load cell
  • Declaration of ATEX conformity of the system (for the code see the pages of the atex weight indicators and MB4 atex barrier kit)
Models Available
 CodeMax Capacity kgMasterpack
4 pcs
 FXC10 10FXC10C
 FXC20 20FXC20C
 FXC50 50FXC50C
 FXC100 100FXC100C
 FXC200 200FXC200C
 FXC300 300FXC300C
 FXC500 500FXC500C

Certification
 CodeDescription 
DCATEXMB4Declaration of ATEX conformity of the whole, Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for NON ATEX weight indicator connected to MB4 Dini Argeo zener barriers, connected to mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). ATEX CONFORMITY DECLARATIONS will be supplied in English.
CCATEXATEX certificate for each load cell for the following categories: II 1G EExia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) and II 1D tD A20 TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C). Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
Dini Argeo S.r.l. P.IVA/VAT IT00767800360 - Copyright 2011 - All Rights Reserved - Privacy Policy www.diniargeo.com